Design of axially and laterally loaded piles using in situ tests: A case history
- 1 November 1985
- journal article
- Published by Canadian Science Publishing in Canadian Geotechnical Journal
- Vol. 22 (4) , 518-527
- https://doi.org/10.1139/t85-072
Abstract
A 915 mm diameter steel pipe pile was driven and tested by the B.C. Ministry of Transportation and Highways as part of their foundation studies for the proposed Annacis channel crossing of the Fraser River. The pile was driven open ended to a maximum depth of 94 m. The pile was tested axially to failure when the pile tip was at depths of 67, 78, and 94 m below ground surface. Following the final axial load test, the pile was loaded laterally to a total deflection at the ground surface of 150 mm. A slope indicator casing was installed in the pile to monitor the deflected shape during lateral loading.Adjacent to the pile, a piezometer-friction cone penetration test (CPT) and a full-displacement pressuremeter profile were made. Results of the axial and lateral load tests are presented along with the data from the CPT and the full-displacement pressuremeter tests. Results of several analyses using the data from the CPT and pressuremeter tests to predict the axial and lateral performance of the pile are presented. A comparison and discussion is presented between the predicted and measured axial and lateral behaviour of the pile, for which excellent agreement was found. Key words: pile load test, cone penetration test, pressuremeter test.Keywords
This publication has 0 references indexed in Scilit: