Diffusion tensor MRI of the human kidney
Top Cited Papers
Open Access
- 26 June 2001
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 14 (1) , 42-49
- https://doi.org/10.1002/jmri.1149
Abstract
This study characterizes the diffusion anisotropy of the human kidney using a diffusion‐weighted, single‐shot echo planar imaging (EPI) sequence in order to access the full apparent diffusion tensor (ADT) within one breathhold. The fractional anisotropy (FA) of the cortex and the medulla were found to be 0.22 ± 0.12 and 0.39 ± 0.11, respectively (N = 10), which emphasizes the need for rotationally invariant diffusion measurements for clinical applications. Additional limitations for clinical diffusion imaging on the kidney are the strong susceptibility variations within the abdomen that restrict the use of imaging techniques employing long echo trains, and the severe motion sensitivity that limits the available imaging time to one breath‐hold. To overcome these problems an isotropic, diffusion‐weighted, segmented EPI protocol that facilitates the acquisition of high‐resolution diffusion‐weighted images within a single breath‐hold was implemented. Using this method, the apparent diffusion coefficient (ADC) of the cortex and medulla were found to be 2.89 ± 0.28 · 10−9 m2/s and 2.18 ± 0.36 · 10−9 m2/s (N = 10). J. Magn. Reson. Imaging 2001;14:42–49.Keywords
This publication has 22 references indexed in Scilit:
- Kardiale Triggerung zur verbesserten abdominellen MR-DiffusionsbildgebungRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2000
- ErratumMagnetic Resonance in Medicine, 1997
- Microstructural and Physiological Features of Tissues Elucidated by Quantitative-Diffusion-Tensor MRIJournal of Magnetic Resonance, Series B, 1996
- Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental resultsMagnetic Resonance in Medicine, 1996
- Inferring microstructural features and the physiological state of tissues from diffusion‐weighted imagesNMR in Biomedicine, 1995
- Feasibility of MR Diffusion Studies in the KidneyJournal of Magnetic Resonance Imaging, 1995
- Diffusion Weighting by the Trace of the Diffusion Tensor within a Single ScanMagnetic Resonance in Medicine, 1995
- Water diffusion and acute strokeMagnetic Resonance in Medicine, 1994
- MR diffusion tensor spectroscopy and imagingBiophysical Journal, 1994
- Correction of motional artifacts in diffusion-weighted MR images using navigator echoesMagnetic Resonance Imaging, 1994