Stromal Thickness in the Normal Cornea: Three-dimensional Display With Artemis Very High-Frequency Digital Ultrasound
- 1 September 2009
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 25 (9) , 776-786
- https://doi.org/10.3928/1081597x-20090813-04
Abstract
Purpose: To characterize the stromal thickness profile in a population of normal eyes. Methods: Stromal thickness profile was measured in vivo by Artemis very high-frequency digital ultrasound scanning (ArcScan, Morrison, Colo) across the central 10-mm corneal diameter on 110 normal eyes. Maps of the average, standard deviation, minimum, maximum, and range of stromal thickness were plotted. The average location of the thinnest stroma was found. The cross-sectional hemi-meridional stromal thickness profile was calculated using annular averaging. The absolute stromal thickness progression relative to the thinnest point was calculated using annular averaging as well as for 8 hemi-meridians individually. Results: The mean stromal thickness at the corneal vertex and at the thinnest point were 465.4±36.9 µ m and 461.8±37.3 µ m, respectively. The thinnest stroma was displaced on average 0.17±0.31 mm inferiorly and 0.33±0.40 mm temporally from the corneal vertex. The average absolute stromal thickness progression from the thinnest point could be described by the quadratic equation: stromal thickness = 6.411 × radius 2 + 2.444 × radius (R 2 = 0.999). Absolute stromal thickness progression was independent of stromal thickness at the thinnest point. The increase in hemi-meridional absolute stromal thickness progression was greatest superiorly and lowest temporally. Conclusions: Three-dimensional thickness mapping of the corneal stroma and stromal thickness progression in a population of normal eyes represent a normative data set, which may help in early diagnosis of corneal abnormalities such as keratoconus and pellucid marginal degeneration. Absolute stromal thickness progression was found to be independent of stromal thickness. [ J Refract Surg . 2009;25:776–786.]Keywords
This publication has 29 references indexed in Scilit:
- Direct residual stromal thickness measurement for assessing suitability for LASIK enhancement by Artemis 3D very high-frequency digital ultrasound arc scanningJournal of Cataract & Refractive Surgery, 2006
- Combined Artemis very high-frequency digital ultrasound-assisted transepithelial phototherapeutic keratectomy and wavefront-guided treatment following multiple corneal refractive proceduresJournal of Cataract & Refractive Surgery, 2006
- Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconusJournal of Cataract & Refractive Surgery, 2006
- Changes in Collagen Orientation and Distribution in Keratoconus CorneasInvestigative Opthalmology & Visual Science, 2005
- Keratoconus StagingCornea, 2004
- X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and LimbusStructure, 2004
- Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatismOphthalmology, 2000
- Three-dimensional ultrasound imaging: Clinical applicationsOphthalmology, 1998
- Central and Peripheral Corneal Thickness in Keratoconus and Normal Patient GroupsOptometry and Vision Science, 1994
- Histopathological Variation in KeratoconusCornea, 1992