Accuracy of Atrial Tachyarrhythmia Detection in Implantable Devices with Arrhythmia Therapies
- 22 July 2004
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 27 (7) , 983-992
- https://doi.org/10.1111/j.1540-8159.2004.00569.x
Abstract
The clinical application of atrial tachyarrhythmia (AT) episode data stored by implantable devices is presently limited by the high proportion of inappropriate detection. We quantified the percentage of inappropriate AT detection in two implantable devices with AT diagnostics and therapies via meta-analysis of stored AT episodes from a number of clinical trials. The AT500 and GEM III AT, contain dual chamber logic to discriminate AT from ventricular tachycardia and far-field R wave (FFRW) oversensing using dual chamber bipolar electrograms. A subset of data from four clinical trials of 1,142 patients was considered. Manual analysis was performed on 21,553 stored episodes with atrial EGM and marker channel from 409 patients with stored episodes and the market-released device detection configuration. The percentage of episodes with inappropriate detection and termination was evaluated and compared between septal and nonseptal lead locations. The percentage of inappropriately detected episodes receiving ATP therapy was also determined. The percentage of episodes appropriately detected and the percentage of net episode duration (i.e., burden) recorded by the device were also determined from a separate analysis of 24-hour Holter recordings from a subset of 40 patients from one trial. Adjusted estimates of the percentage of inappropriate detection were 95.3% (93.5–96.7; 95% CI) for AT500 and 95.7% (84.3–98.9) for GEM III AT. Inappropriate detection was primarily due to FFRW oversensing or brief runs of premature atrial contractions (PACs). The device detected 100% of the sustained atrial arrhythmia episodes and 95.3% (range 76.1–99.9) of the net AT duration observed on the Holter recordings. AT detection was not influenced by atrial lead location. Appropriate detection of normal sinus rhythm at episode termination was 83.7% (80.7–86.3) for AT500 and 92.1% (84.5–96.2) for GEM III AT. Accurate detection and discrimination of FFRWs validates the reliability of AT diagnostic data and decreases the risk of inappropriate device therapy. (PACE 2004; 27:983–992)Keywords
This publication has 22 references indexed in Scilit:
- Combined Efficacy of Atrial Septal Lead Placement and Atrial Pacing Algorithms for Prevention of Paroxysmal Atrial TachyarrhythmiaJournal of Cardiovascular Electrophysiology, 2003
- Incremental programming of atrial anti-tachycardia pacing therapies in bradycardia-indicated patients: effects on therapy efficacy and atrial tachyarrhythmia burdenEP Europace, 2003
- A new pacemaker algorithm for the treatment of atrial fibrillationJournal of the American College of Cardiology, 2003
- The effect of atrial pacing therapies on atrial tachyarrhythmia burden and frequencyJournal of the American College of Cardiology, 2003
- A Comparison of Rate Control and Rhythm Control in Patients with Atrial FibrillationNew England Journal of Medicine, 2002
- Atrial Therapies Reduce Atrial Arrhythmia Burden in Defibrillator PatientsCirculation, 2001
- The use of permanent pacemakers in the detection of cardiac arrhythmiasEP Europace, 2001
- Critical Analysis of Dual-Chamber Implantable Cardioverter-Defibrillator Arrhythmia DetectionCirculation, 2001
- Detection of Atrial Fibrillation and Flutter by a Dual-Chamber Implantable Cardioverter-DefibrillatorCirculation, 2000
- Is the Atrial High Rate Episode Diagnostic Feature Reliahle in Detecting Paroxysmal Episodes of Atrial Tachyarrhythmias?Pacing and Clinical Electrophysiology, 1998