Motion of the distal renal artery during three‐dimensional contrast‐enhanced breath‐hold MRA
- 25 November 2002
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 16 (6) , 685-696
- https://doi.org/10.1002/jmri.10214
Abstract
Purpose To study the potential detrimental effects of renal motion on breath‐hold three‐dimensional contrast‐enhanced (CE) magnetic resonance angiography (MRA). Materials and Methods A computer model simulating linear motion was applied to MRA pulse sequences. Subsequently, to study whether renal motion was present, 24 patients being evaluated for possible renovascular hypertension underwent a breath‐hold nonenhanced single slice two‐dimensional dynamic turbo field‐echo magnetic resonance imaging (MRI) scan with a typical duration of 32 seconds. This sequence was followed by breath‐hold three‐dimensional CE renal MRA. CE‐MRA images were evaluated by two independent observers. Results The computer model revealed linear renal motion to cause artifacts. The severity of these artifacts correlated with velocity. Significant (P < 0.001) near linear cranial motion of the kidneys and diaphragm during a sustained breath‐hold was found for the right kidney, left kidney, right diaphragm, and left diaphragm (0.26 ± 0.21 mm/second, 0.25 ± 0.23 mm/second, 0.43 ± 0.43 mm/second, and 0.29 ± 0.33 mm/second [mean ± SD], respectively). CE‐MRA images showed artifacts of the distal renal artery that corroborated the computer model findings. Conclusion The observed cranial motion of the kidneys during a breath‐hold adversely affects distal renal artery image quality on three‐dimensional CE‐MRA and jeopardizes reliable clinical evaluation. Shortening scan time may be beneficial for decreasing image degradation caused by this phenomenon. J. Magn. Reson. Imaging 2002;16:685–696. Published 2002 Wiley‐Liss, Inc.Keywords
This publication has 25 references indexed in Scilit:
- Detection of Renal Artery StenosisAmerican Journal of Roentgenology, 2001
- Diagnostic Tests for Renal Artery Stenosis in Patients Suspected of Having Renovascular HypertensionAnnals of Internal Medicine, 2001
- Renal arteriography using gadolinium enhanced 3D MR angiography—clinical experience with the technique, its limitations and pitfallsThe British Journal of Radiology, 2001
- Trends in Adverse Events After IV Administration of Contrast MediaAmerican Journal of Roentgenology, 2001
- Assessment of Gadolinium-Enhanced Time-Resolved Three-Dimensional MR Angiography for Evaluating Renal Artery StenosisAmerican Journal of Roentgenology, 2001
- High-Spatial-Resolution Contrast-enhanced MR Angiography of the Renal Arteries: A Prospective Comparison with Digital Subtraction AngiographyRadiology, 2001
- NONINASIVE INVESTIGATION FOR RENAL ARTERY STENOSIS: CONTRAST-ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY AND COLOR DOPPLER SONOGRAPHY AS COMPARED TO DIGITAL SUBTRACTION ANGIOGRAPHYClinical and Experimental Hypertension, 2001
- The Effect of Balloon Angioplasty on Hypertension in Atherosclerotic Renal-Artery StenosisNew England Journal of Medicine, 2000
- PREOPERATIVE EVALUATION OF LIVING RENAL DONORS WITH GADOLINIUM-ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY1Transplantation, 1999
- Evaluation of renal artery stenosis with dynamic gadolinium-enhanced MR angiography.American Journal of Roentgenology, 1997