Feasibility study of a compact high resolution dual layer LSO-APD detector module for positron emission tomography
- 28 November 2002
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1199-1203 vol.2
- https://doi.org/10.1109/nssmic.1998.774374
Abstract
An existing high resolution scanner for positron emission tomography (PET) of small animals was modified to investigate a scheme of depth-of-interaction (DOI) detection. The detectors were based on the readout of small (3.7/spl times/3.7/spl times/12 mm/sup 3/) lutetium oxyorthosilicate (LSO) crystals with avalanche photodiodes (APD). For DOI measurements, 4 detector modules (arrays of 2/spl times/8 LSO-APD detectors) were mounted on a rotatable gantry in a dual layer setup. The energy resolution at 511 keV of a detector in the first layer was 17.7% (FWHM), decreasing to 19.3% in the second layer. The intrinsic resolution using detectors in the front layer varied between 2.1 mm and 3.5 mm. Combinations of crystals in the second layer yielded intrinsic resolutions of 2.0 mm to 2.8 mm (FWHM). The systems sensitivity could be increased by 20% when data of the second layer was included. Reconstruction of a /sup 18/F line source yielded a tomographic image resolution of 2.5 mm to 2.6 mm, depending on the usage of data from different layers. Without DOI information, the spatial resolution was 3.0 mm (FWHM). Although a degradation in energy resolution was observed in the dual layer setup compared to only one layer, this study showed the feasibility of individual readout in a dual layer module for improved sensitivity and sampling.Keywords
This publication has 10 references indexed in Scilit:
- Segmented LSO crystals for depth-of-interaction encoding in PETIEEE Transactions on Nuclear Science, 1998
- Studies with a prototype high resolution PET scanner based on LSO-APD modulesIEEE Transactions on Nuclear Science, 1998
- A GSO depth of interaction detector for PETIEEE Transactions on Nuclear Science, 1998
- A YSO/LSO phoswich array detector for single and coincidence photon imagingIEEE Transactions on Nuclear Science, 1998
- Algorithms to identify detector Compton scatter in PET modulesIEEE Transactions on Nuclear Science, 1996
- A study of inter-crystal scatter in small scintillator arrays designed for high resolution PET imagingIEEE Transactions on Nuclear Science, 1996
- Design studies for a PET detector module using a PIN photodiode to measure depth of interactionIEEE Transactions on Nuclear Science, 1994
- Dynamic high resolution imaging of rats: design considerationsIEEE Transactions on Nuclear Science, 1991
- Study of the resolution performance of an array of discrete detectors with independent readouts for positron emission tomographyIEEE Transactions on Medical Imaging, 1991
- Design of a high resolution positron emission tomograph using solid state scintillation detectorsIEEE Transactions on Nuclear Science, 1988