Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Top Cited Papers
- 1 March 2000
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 19 (3) , 203-210
- https://doi.org/10.1109/42.845178
Abstract
We describe an automated method to locate and outline blood vessels in images of the ocular fundus. Such a tool should prove useful to eye care specialists for purposes of patient screening, treatment evaluation, and clinical study. Our method differs from previously known methods in that it uses local and global vessel features cooperatively to segment the vessel network. We evaluate our method using hand-labeled ground truth segmentations of 20 images. A plot of the operating characteristic shows that our method reduces false positives by as much as 15 times over basic thresholding of a matched filter response (MFR), at up to a 75% true positive rate. For a baseline, we also compared the ground truth against a second hand-labeling, yielding a 90% true positive and a 4% false positive detection rate, on average. These numbers suggest there is still room for a 15% true positive rate improvement, with the same false positive rate, over our method. We are making all our images and hand labelings publicly available for interested researchers to use in evaluating related methods.Keywords
This publication has 17 references indexed in Scilit:
- A methodology for evaluating range image segmentation techniquesPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Locating blood vessels in retinal images by piecewise threshold probing of a matched filter responseIEEE Transactions on Medical Imaging, 2000
- Mapping the human retinaIEEE Transactions on Medical Imaging, 1998
- Reconstruction of vascular networks using three-dimensional modelsIEEE Transactions on Medical Imaging, 1997
- An experimental comparison of range image segmentation algorithmsIEEE Transactions on Pattern Analysis and Machine Intelligence, 1996
- Back-propagation network and its configuration for blood vessel detection in angiogramsIEEE Transactions on Neural Networks, 1995
- A 3D reconstruction of vascular structures from two X-ray angiograms using an adapted simulated annealing algorithmIEEE Transactions on Medical Imaging, 1994
- Detection of blood vessels in retinal images using two-dimensional matched filtersIEEE Transactions on Medical Imaging, 1989
- A method for a fully automatic definition of coronary arterial edges from cineangiogramsIEEE Transactions on Medical Imaging, 1988
- A new method for estimation of coronary artery dimensions in angiogramsIEEE Transactions on Acoustics, Speech, and Signal Processing, 1988