Sparse random ultrasound phased array for focal surgery
- 1 November 1996
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 43 (6) , 1111-1121
- https://doi.org/10.1109/58.542054
Abstract
Ultrasound phased arrays offer several advantages over single focused transducer technology, enabling electronically programmable synthesis of focal size and shape, as well as position. While phased arrays have been employed for medical diagnostic and therapeutic (hyperthermia) applications, there remain fundamental problems associated with their use for surgery. These problems stem largely from the small size of each array element dictated by the wavelength employed at surgical application frequencies (2-4 MHz), the array aperture size required for the desired focal characteristics, and the number of array elements and electronic drive channels required to provide RF energy to the entire array. The present work involves the theoretical and experimental examination of novel ultrasound phased arrays consisting of array elements larger than one wavelength, minimizing the number of elements in an aperture through a combination of geometric focusing, directive beams, and sparse random placement of array elements, for tissue ablation applications. A hexagonally packed array consisting of 108 8-mm-diameter circular elements mounted on a spherical shell was modeled theoretically and a prototype array was constructed to examine the feasibility of sparse random array configurations for focal surgery. A randomly selected subset of elements of the prototype test array (64 of 108 available channels) was driven at 2.1 MHz with a 64-channel digitally controlled RF drive system. The performance of the prototype array was evaluated by comparing field data obtained from theoretical modeling to that obtained experimentally via hydrophone scanning. The results of that comparison, along with total acoustic power measurements, suggest that the use of sparse random phased arrays for focal surgery is feasible, and that the nature of array packing is an important determinant to observed performance.Keywords
This publication has 27 references indexed in Scilit:
- Optimizing the radiation pattern of sparse periodic two-dimensional arraysIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1996
- Experimental evaluation of a prototype cylindrical section ultrasound hyperthermia phased-array applicatorIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1991
- Ability of high-intensity ultrasound to ablate human atherosclerotic plaques and minimize debris sizeThe American Journal of Cardiology, 1991
- Sound field calculation for rectangular sourcesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1989
- Threshold dosages for damage to mammalian liver by high intensity focused ultrasoundIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1988
- Continuous-wave pressure fields of ultrasonic transducersThe Journal of the Acoustical Society of America, 1986
- Transkull focal lesions in cat brain produced by ultrasoundJournal of Neurosurgery, 1981
- Tumor irradiation with intense ultrasoundUltrasound in Medicine & Biology, 1978
- Thresholds for Focal Ultrasonic Lesions in Rabbit Kidney, Liver, and TesticleIEEE Transactions on Biomedical Engineering, 1977
- An Analysis of Lesion Development in the Brain and in Plastics by High-Intensity Focused Ultrasound at Low-Megahertz FrequenciesThe Journal of the Acoustical Society of America, 1972