Use of 1.5-μm Porous Ethyl-Bridged Hybrid Particles as a Stationary-Phase Support for Reversed-Phase Ultrahigh-Pressure Liquid Chromatography
- 7 August 2004
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (18) , 5441-5450
- https://doi.org/10.1021/ac049643d
Abstract
A new ethyl-bridged hybrid packing material was evaluated in terms of its suitability for ultrahigh-pressure liquid chromatography (UHPLC). The 1.5-microm particles were obtained and packed into 30-microm-i.d. fused-silica capillary columns up to 50 cm in length. The particles were evaluated by isocratic reversed-phase UHPLC at pressures up to 4500 bar (65,000 psi). The chromatographic performance of these particles was found to be similar to the performance of 1.0-microm nonporous silica particles. The mechanical strength of the ethyl-bridged hybrid material was evaluated by running a 15-cm-long column at pressures up to 4500 bar. No breakdown of the particles in the packed bed was observed. The sample loading capacity of the hybrid material was evaluated and compared to 1.0-microm nonporous silica material by observing analyte peak width versus amount injected. The observed improvement in loading capacity for the hybrid material versus nonporous silica was consistent with the improvement predicted by comparing the phase ratios of the two materials.Keywords
This publication has 8 references indexed in Scilit:
- Characterization and Evaluation of C18 HPLC Stationary Phases Based on Ethyl-Bridged Hybrid Organic/Inorganic ParticlesAnalytical Chemistry, 2003
- Safety concerns in ultrahigh pressure capillary liquid chromatography using air-driven pumpsJournal of Chromatography A, 2003
- Measuring the translational diffusion coefficients of small DNA molecules by capillary electrophoresisBiopolymers, 2001
- Ultrahigh-Pressure Reversed-Phase Capillary Liquid Chromatography: Isocratic and Gradient Elution Using Columns Packed with 1.0-μm ParticlesAnalytical Chemistry, 1999
- Ultrahigh-Pressure Reversed-Phase Liquid Chromatography in Packed Capillary ColumnsAnalytical Chemistry, 1997
- Nondependence of diffusion-controlled peak dispersion on diffusion coefficient and ionic mobility in capillary zone electrophoresis without electroosmotic flowAnalytical Chemistry, 1991
- Capillary zone electrophoresis for the determination of electrophoretic mobilities and diffusion coefficients of proteinsJournal of Microcolumn Separations, 1989
- Preparation of monodisperse silica particles: Control of size and mass fractionJournal of Non-Crystalline Solids, 1988