Although several methods have been used clinically to assess aortic regurgitation (AR), there is no “gold standard” for regurgitant volume measurement. Magnetic resonance phase velocity mapping (PVM) can be used for noninvasive blood flow measurements. To evaluate the accuracy of PVM in quantifying AR with a single imaging slice in the ascending aorta, in vitro experiments were performed by using a compliant aortic model. Attention was focused on determining the slice location that provided the best results. The most accurate measurements were taken between the aortic valve annulus and the coronary ostia where the measured (Y) and actual (X) flow rate had close agreement (Y = 0.954 × + 0.126, r2 = 0.995, standard deviation of error = 0.139 L/min). Beyond the coronary ostia, coronary flow and aortic compliance negatively affected the accuracy of the measurements. In vivo measurements taken on patients with AR showed the same tendency with the in vitro results. In making decisions regarding patient treatment, diagnostic accuracy is very important. The results from this study suggest that higher accuracy is achieved by placing the slice between the aortic valve and the coronary ostia and that this is the region where attention should be focused for further clinical investigation.Keywords
This publication has 31 references indexed in Scilit:
- Quantitative assessment of aortic regurgitation by combined two-dimensional, continuous-wave and colour flow Doppler measurementsJournal of Internal Medicine, 1992
- The JH/LVOH Method in the Quantification of Aortic Regurgitation: How the Cardiac Sonographer May Avoid an Important Potential PitfallJournal of the American Society of Echocardiography, 1991
- Cine MR imaging of valvular heart disease: display and imaging parameters affect the size of the signal void caused by valvular regurgitation.American Journal of Roentgenology, 1990
- Aortic valve morphology: An important in vitro determinant of proximal regurgitant jet width by Doppler color flow mappingJournal of the American College of Cardiology, 1990
- Estimation of regurgitant volume and orifice in aortic regurgitation combining CW Doppler and parameter estimation in a Windkessel-like modelIEEE Transactions on Biomedical Engineering, 1990
- Diagnostic accuracy and estimation of the severity of valvular regurgitation from the signal void on cine magnetic resonance imagesAmerican Heart Journal, 1989
- Evaluation of aortic insufficiency by Doppler color flow mappingJournal of the American College of Cardiology, 1987
- Calculation of pulsed Doppler left ventricular outflow tract regurgitant index for grading the severity of aortic regurgitationAmerican Heart Journal, 1984
- Limitations of qualitative angiographic grading in aortic or mitral regurgitationThe American Journal of Cardiology, 1984
- Pulsed Doppler echocardiography in the diagnosis and estimation of severity of aortic insufficiencyThe American Journal of Cardiology, 1982