Swelling and Thermal Properties of Poly(Vinyl Alcohol) Containing Hemoglobin Membranes
- 1 May 1999
- journal article
- research article
- Published by SAGE Publications in Journal of Bioactive and Compatible Polymers
- Vol. 14 (3) , 243-257
- https://doi.org/10.1177/088391159901400304
Abstract
Poly(vinyl alcohol) (PVA), a hydrophilic polymer bearing hydroxyl functional groups, readily forms gels on the addition of a bifunctional agent such as glutaraldehyde. This gelation is caused by the formation of acetal bonds between the aldehyde groups and the hydroxyl groups, in the presence of HCL. The crosslink density is easily controlled by changing the concentration of glutaraldehyde, offering a way to control the total water content and, consequently, the permeability. Strong transparent films were obtained by drying these gels. These were suitable for supporting biologically active molecules, providing a viable, better alternative to the usual PVA gels which are physically crosslinked. To establish the relationship between their thermal properties and the occurrence of the physical or chemical gelling, their water vapor sorption and thermal behavior were investigated and compared. PVA/glutaraldehyde membranes were prepared with immobilized hemoglobin for bilirubin analysis. Assisted by the respective equilibrium swelling ratio and thermal stability data, it was found that, for these particular PVA/hemoglobin membranes, the occurrence of either chemical or physical crosslinking is mainly determined by the Hb/HCl ratio.Keywords
This publication has 22 references indexed in Scilit:
- A fiber optic sensor for rapid analysis of bilirubin in serumAnalytica Chimica Acta, 1997
- Chemiluminescence arising from the oxidation of bilirubin in aqueous mediaAnalytica Chimica Acta, 1996
- A new type of ALSS — the preparation of crosslinked chitosan resins and its adsorption properties for bilirubinReactive and Functional Polymers, 1996
- Enzyme electrode for the determination of bilirubinElectroanalysis, 1996
- Determination of Bilirubin by Fiberoptic BiosensorAnalytical Letters, 1996
- Study of an enzyme coupled system for the development of fibre optical bilirubin sensorsBiosensors and Bioelectronics, 1996
- pH-Sensitive HydrogelsPublished by American Chemical Society (ACS) ,1992
- Cofactor-containing bioluminescent fibre-optic sensor: new developments with poly(vinyl alcohol) matricesAnalytica Chimica Acta, 1991
- Gelled Aqueous SystemsPublished by American Chemical Society (ACS) ,1989
- Rheological and DSC changes in poly(vinyl alcohol) gels induced by immersion in waterJournal of Polymer Science: Polymer Physics Edition, 1985