Third‐trimester fetal MRI in isolated 10‐ to 12‐mm ventriculomegaly: is it worth it?
- 18 July 2006
- journal article
- Published by Wiley in BJOG: An International Journal of Obstetrics and Gynaecology
- Vol. 113 (8) , 942-947
- https://doi.org/10.1111/j.1471-0528.2006.01003.x
Abstract
The justification for magnetic resonance imaging (MRI) in isolated mild ventriculomegaly remains controversial. This study was undertaken to evaluate the contribution of third-trimester MRI in isolated 10- to 12-mm fetal ventriculomegaly. Observational prospective cohort study. Universitary prenatal reference centre. From February 2000 to May 2005, we prospectively collected data concerning fetuses referred to us for cerebral MRI following detection of ventriculomegaly by ultrasound scan (n= 310). Among these, we identified and analysed those cases in which ventriculomegaly was isolated and did not exceed 12 mm in ultrasound examinations prior to MRI scan (n= 185). Cases in which MRI provided additional information that was likely to have an impact on prenatal management were detailed. During the study period, 310 MRI were performed because of fetal ventriculomegaly. Hundred and eighty-five were suspected to be isolated 10- to 12-mm ventriculomegalies in ultrasound scan and formed our database. MRI confirmed the 10- to 12-mm isolated fetal ventriculomegaly in 106 cases (57.3%) and found other abnormalities in 5 (4.7%) of these 106 cases. MRI found ventricular measurement to be less than 10 mm in 43 cases (23.3%) and more than 12 mm in 36 cases (19.4%). Among these 36 fetuses with ventricle size more than 12 mm, 6 (16.7%) had other abnormalities, whereas MRI did not find other abnormalities in the 43 cases with ventricle size below 10 mm. Before advantages of MRI to ultrasound examination can be demonstrated, it seems reasonable that MRI should remain an investigational tool, restricted to selected clinical situations in which the results are expected to modify case management. Where ultrasound scan suspects isolated ventriculomegaly of 10 to 12 mm, our data suggest that when the finding is confirmed with MRI this could be expected in around 5% of cases. Therefore, the policy of routine MRI in such cases should depend on prenatal centres' priorities.Keywords
This publication has 24 references indexed in Scilit:
- Coronal measurement of the fetal lateral ventricles: comparison between ultrasonography and magnetic resonance imagingUltrasound in Obstetrics & Gynecology, 2005
- Imaging of fetal cerebral ventriculomegaly: A guide to management and outcomeSeminars in Fetal and Neonatal Medicine, 2005
- Fetal cerebral ventriculomegaly: outcome in 176 casesUltrasound in Obstetrics & Gynecology, 2005
- Comparison of ultrasound and magnetic resonance imaging in 100 singleton pregnancies with suspected brain abnormalitiesBJOG: An International Journal of Obstetrics and Gynaecology, 2004
- Mild Fetal Cerebral Ventriculomegaly: Diagnosis, Clinical Associations, and OutcomesObstetrical & Gynecological Survey, 2003
- Is fetal magnetic resonance imaging superior to neurosonography for detection of brain anomalies?Ultrasound in Obstetrics & Gynecology, 2002
- Prenatal diagnosis and follow‐up of 14 cases of unilateral ventriculomegalyUltrasound in Obstetrics & Gynecology, 1999
- The clinical significance of fetal isolated cerebral borderline ventriculomegaly: report of 31 cases and review of the literatureUltrasound in Obstetrics & Gynecology, 1999
- Transient unilateral ventriculomegaly: Sonographic diagnosis during the second trimester of pregnancyJournal of Clinical Ultrasound, 1994
- Fetal mild idiopathic lateral ventriculomegaly: is there a correlation with fetal trisomy?Ultrasound in Obstetrics & Gynecology, 1993