Evaluation of catheters and metallic catheter markers as calibration standard for measurement of coronary dimension
- 1 November 1990
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 21 (3) , 148-153
- https://doi.org/10.1002/ccd.1810210305
Abstract
Measurement of coronary dimension requires an accurate and reproducible dimensional reference. Angiographic catheters are frequently used for this purpose. We measured the angiographic diameters of a broad range of diagnostic and angioplasty guiding catheters by using two commonly used edge‐detection algorithms. Angiographic diameters are significantly less than true catheter outer diameter. Therefore the use of contrast‐filled catheters as a dimensional reference may lead to considerable error in vessel measurement with overestimation of absolute dimension. Tables of reference values for multiple catheters are included. We also evaluated the suitability of a metallic‐tipped “marker” catheter as calibration standard, tested under a variety of angiographic conditions. The metallic‐tipped marker was found to have a better degree of reproducibility than catheters. These findings have implications for studies employing serial measurements of coronary artery dimension and for the clinical practice of estimating vessel diameter for choice of balloon size during angioplasty.Keywords
This publication has 14 references indexed in Scilit:
- The use of biplane angiocardiography for the measurement of left ventricular volume in manPublished by Elsevier ,2004
- Use of a metal ring‐marked catheter for geometric calibration in quantitative coronary angiographyCatheterization and Cardiovascular Diagnosis, 1988
- Optimal detection of the progression of coronary artery disease: comparison of methods suitable for risk factor intervention trials.Circulation, 1986
- Changes in cross-sectional area of the coronary lumen in the six months after angioplasty: a quantitative analysis of the variable response to percutaneous transluminal angioplasty.Circulation, 1986
- Estimation of the effects of angioplasty on coronary stenosis using quantitative video angiographyCatheterization and Cardiovascular Diagnosis, 1985
- Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: Diameter versus densitometric area measurementsThe American Journal of Cardiology, 1984
- Computerized image analysis for quantitative measurement of vessel diameter from cineangiograms.Circulation, 1983
- Reliability of assessing change with sequential coronary angiographyAmerican Heart Journal, 1982
- The mechanisms of nitroglycerin action: stenosis vasodilatation as a major component of the drug response.Circulation, 1981
- Quantitative coronary arteriography: estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation.Circulation, 1977