New horizons in human biomonitoring of environmentally and occupationally relevant metals—sector-field ICP-MS versus electrothermal AAS
- 7 January 2000
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 15 (4) , 347-352
- https://doi.org/10.1039/a909056h
Abstract
Sector-field ICP-MS (SF-ICP-MS) was used for the quasi-simultaneous determination of selected trace and ultra-trace elements of occupational and environmental interest, such as Al, Co, Cr, Cu, Fe, Mn, Ni, Pt, V and Zn, in human urine and serum. In the case of urine, Pb, Cd and Tl were additionally determined. Sample pretreatment was restricted to UV photolysis and to a subsequent moderate dilution with 0.5% HNO3 solution without using any chemical separation and enrichment. Contamination was carefully controlled at each step of the analytical procedure. Calibration was carried out by the standard addition procedure. Owing to spectral interferences, the determination of Al, Co, Cr, Cu, Fe, Ni, V and Zn was performed in the medium resolution (MR) mode (m/Δm ≅ 3000), while the determination of non-interfered elements, such as Cd, Mn, Pb, Pt and Tl, was carried out at low resolution (LR) to gain a maximum of sensitivity. The accuracy of the procedure was checked by the analysis of commercially available quality control serum and urine samples, by comparison with electrothermal (ET-)AAS as a second independent method and by successful participation in an inter-laboratory comparison programme. The results obtained with both methods were in excellent agreement. Regarding the quality control materials, good agreement was also achieved between the found and assigned values. The described SF-ICP-MS multi-element method is thus suitable for the quasi-simultaneous determination of trace and ultra-trace elements in urine and serum covering a wide range of concentrations. It is especially valuable for rapid multi-element screening purposes in cases of unknown exposures (non-target screening) and for determinations at very low concentrations, which are not accessible to AAS techniques.Keywords
This publication has 18 references indexed in Scilit:
- The only general method for overcoming spectroscopic interference requires double-focusing instrumentation.: Double-Focusing Mass Spectrometers in ICPMSAnalytical Chemistry, 1998
- Atomic Spectrometry Update–Clinical and biological materials, food and beveragesJournal of Analytical Atomic Spectrometry, 1998
- Determination of physiological palladium and platinum levels in urine using double focusing magnetic sector field ICP-MSAnalytical and Bioanalytical Chemistry, 1997
- Method for the determination of thorium and uranium in urine by ICP-MSMicrochimica Acta, 1997
- Determination of physiological noble metals in human urine using liquid-liquid extraction and Zeeman electrothermal atomic absorption spectrometryAnalytica Chimica Acta, 1997
- gDouble-focusing Sector Field Inductively Coupled Plasma Mass Spectrometry for Highly Sensitive Multi-element and Isotopic AnalysisJournal of Analytical Atomic Spectrometry, 1997
- Determination of Trace and Ultratrace Elements in Human Serum With a Double Focusing Magnetic Sector Inductively Coupled Plasma Mass SpectrometerJournal of Analytical Atomic Spectrometry, 1997
- ICP‐MS bei biologischen ProbenNachrichten aus Chemie, Technik und Laboratorium, 1996
- High resolution ICP-MS ? a new concept for elemental mass spectrometryAnalytical and Bioanalytical Chemistry, 1994
- Spectral interferences encountered in the analysis of biological materials by inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1994