Esophageal Stethoscope Placement Depth
- 1 June 1998
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 86 (6) , 1276-1279
- https://doi.org/10.1097/00000539-199806000-00027
Abstract
Although the esophageal stethoscope has been used for many years, the effect of the depth of placement on the quality of the sounds obtained has never been investigated. The amplitude and frequency characteristics of the first and second heart sound and of inspiratory and expiratory breath sounds were determined at various stethoscope depths (from the distal tip) in 17 healthy anesthetized adults. The amplitude for each type of sound varied markedly with depth. Maximal amplitude for S1 was at 34 +/- 3 cm, for S2 at 27 +/- 2 cm, for inspiratory breath sound at 28 +/- 2 cm, and for expiratory breath sound at 26 +/- 2 cm. There was a positive linear correlation between the depth of maximal amplitude of these sounds and patient height. Peak frequency, in general, did not change with depth. We conclude that investigators should measure and document depth when performing studies involving the esophageal stethoscope. Analysis of sound from the esophageal stethoscope at various depths reveals that placement depth greatly affects the sounds. A depth of 28-32 cm is recommended for clinical use; S1, S2, and inspiratory and expiratory sounds have a high amplitude in that range.Keywords
This publication has 8 references indexed in Scilit:
- Estimation of pulmonary artery pressure by spectral analysis of the second heart soundThe American Journal of Cardiology, 1996
- Use of esophageal or precordial stethoscopes by anesthesia providers: Are we listening to our patients?Journal of Clinical Anesthesia, 1995
- Repeatability of measurements of normal lung sounds.American Journal of Respiratory and Critical Care Medicine, 1994
- The Stethoscope: Applications and Limitations– An Analysis of 2000 Incident ReportsAnaesthesia and Intensive Care, 1993
- Airway Considerations in the Management of Patients Requiring Long-Term Endotracheal IntubationAnesthesia & Analgesia, 1992
- Placement of esophageal stethoscope by acoustic criteria does not consistently yield an optimal location for the monitoring of core temperatureJournal of Clinical Monitoring and Computing, 1990
- Exploration of the cause of the low intensity aortic component of the second sound in nonhypotensive patients with poor ventricular performance.Circulation, 1978
- MAINTENANCE OF STERILE ANESTHESIA EQUIPMENTAnesthesiology, 1954