Respiratory motion in coronary magnetic resonance angiography: A comparison of different motion models
- 24 May 2002
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 15 (6) , 661-671
- https://doi.org/10.1002/jmri.10112
Abstract
Purpose To assess respiratory motion models for coronary magnetic resonance angiography (CMRA). In this study various motion models that describe the respiration‐induced 3D displacements and deformations of the main coronary arteries were compared. Materials and Methods Multiple high‐resolution 3D coronary MR images were acquired in healthy volunteers using navigator‐based respiratory gating, each depicting the coronary vessels at different respiratory motion states. In the images representing the different inspiratory states the displacements and deformations of the main coronary vessels with respect to the end‐expiratory state were determined, by means of elastic registration. Several correction models (superior‐inferior (SI) translation, 3D translation, and 3D affine transformation) were tested and compared with respect to their ability to map a selected inspiratory to the end‐expiratory motion state. Results 3D translation was found to be superior over SI translation, which is commonly used for prospective motion correction in CMRA. The 3D affine transformation was found to be the best correction model considered in this study. Furthermore, a large intersubject variability of the model parameters was observed. Conclusion The results of this study indicate that a patient‐adapted 3D correction model (3D translation or better 3D affine) will considerably improve prospective motion correction in CMRA. J. Magn. Reson. Imaging 2002;15:661–671.Keywords
This publication has 26 references indexed in Scilit:
- Accelerated coronary MRA by simultaneous acquisition of multiple 3D stacksJournal of Magnetic Resonance Imaging, 2001
- Motion artifact reduction and vessel enhancement for free-breathing navigator-gated coronary MRA using 3Dk-space reorderingMagnetic Resonance in Medicine, 2001
- The real-time interactive 3-D-DVA for robust coronary MRAIEEE Transactions on Medical Imaging, 2000
- An improved algorithm for rotational motion artifact suppression in MRIIEEE Transactions on Medical Imaging, 1998
- Motion‐adapted gating based on k‐space weighting for reduction of respiratory motion artifactsMagnetic Resonance in Medicine, 1997
- Prospective adaptive navigator correction for breath‐hold MR coronary angiographyMagnetic Resonance in Medicine, 1997
- Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary ImagingMagnetic Resonance in Medicine, 1995
- Coronary Angiography with Magnetization‐Prepared T2 ContrastMagnetic Resonance in Medicine, 1995
- Real‐time motion detection in spiral MRI using navigatorsMagnetic Resonance in Medicine, 1994
- A respiratory motion artifact reduction method in magnetic resonance imaging of the chestIEEE Transactions on Medical Imaging, 1991