Peripheral “Oscillatory” Compliance Is Associated With Aortic Augmentation Index
- 1 June 2001
- journal article
- other
- Published by Wolters Kluwer Health in Hypertension
- Vol. 37 (6) , 1434-1439
- https://doi.org/10.1161/01.hyp.37.6.1434
Abstract
—The augmentation index (AIx) and “oscillatory” compliance (C 2 ) are wave contour analysis parameters for the central aorta (P ao ) and radial artery pressure wave (P rad ), respectively. Both are sensitive to cardiovascular risk factors such as aging, hypertension, and diabetes and have been proposed as prognostic markers for cardiovascular disease. In this work, we studied the relation between both. We first calculated P rad corresponding to a typical aortic A-type (AIx >0.15) and C-type wave (AIx rad corresponding to C-type waves yielded the highest C 2 value. We further used simultaneously measured aortic and radial artery pressure in 45 human subjects age 34 to 84 years (63±12 [SD]) at baseline and after administration of nitroglycerin to calculate AIx meas and C 2 , respectively. Transfer function was used to calculate reconstructed aortic pressure and AIx rec . AIx rec underestimates AIx meas by 0.03±0.16, but both values correlate well ( r =0.64; P 2 and AIx were inversely correlated ( r =−0.36; P meas ; r =−0.30; P rec ). Both AIx meas (0.06±0.17 versus 0.20±0.21; P rec (0.04±0.12 versus 0.16±0.16; P 2 increased only nonsignificantly (0.080±0.036 versus 0.071±0.042). C 2 is related to AIx and reflects, at least in part, hemodynamic changes affecting central aortic pressure. Nevertheless, given the model assumptions and computational steps associated with calculating C 2 , AIx could be a more appropriate parameter to use in the clinical setting because it is determined directly from the pressure wave contour.Keywords
This publication has 13 references indexed in Scilit:
- Individualizing the aorto-radial pressure transfer function: feasibility of a model-based approachAmerican Journal of Physiology-Heart and Circulatory Physiology, 2000
- Augmentation of central arterial pressure in type 1 diabetes.Diabetes Care, 1999
- Arterial stiffnessJournal Of Hypertension, 1999
- Fit to diastolic arterial pressure by third-order lumped model yields unreliable estimates of arterial complianceMedical Engineering & Physics, 1996
- Vascular abnormalities in non-insulin-dependent diabetes mellitus identified by arterial waveform analysisThe American Journal of Medicine, 1993
- An analysis of the relationship between central aortic and peripheral upper limb pressure waves in manEuropean Heart Journal, 1993
- Assessment of arterial compliance in hypertensionCurrent Opinion in Nephrology and Hypertension, 1993
- Arterial stiffness, systolic blood pressure, and logical treatment of arterial hypertension.Hypertension, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Forward and backward waves in the arterial systemCardiovascular Research, 1972