Pivotal, randomized U.S. study of the Symbiot™ covered stent system in patients with saphenous vein graft disease: Eight‐month angiographic and clinical results from the Symbiot III trial
- 4 August 2006
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 68 (3) , 379-388
- https://doi.org/10.1002/ccd.20873
Abstract
Objectives: The purpose of this study was to evaluate the clinical and angiographic outcomes of the Symbiot ePTFE covered stent versus bare metal stents (BMS) for the treatment of saphenous vein graft (SVG) disease. Background: The Symbiot stent was developed to reduce periprocedural complications, by potentially preventing distal embolization, and to serve as a possible barrier to cell migration, thus reducing restenosis. Methods: Symbiot III is a prospective, randomized trial of 400 patients at 45 US sites, with 201 patients in the Symbiot group and 199 in the BMS group. Randomization was stratified based on the intended use of embolic protection devices and glycoprotein IIb/IIIa inhibitors. The primary endpoint was percent diameter stenosis (%DS) as measured by quantitative coronary angiography at 8 months. Secondary endpoints included MACE (cardiac death, MI, TVR). Results: The groups were well matched for all baseline clinical and lesion characteristics. At 8 months, %DS was comparable between groups (30.9% Symbiot, 31.9% BMS, P = 0.80). Although the rates of binary restenosis in the stented segment were similar (29.1% Symbiot, 21.9% BMS, P = 0.17), more patients in the Symbiot group had binary restenosis at the proximal edge (9.0% Symbiot, 1.8% BMS, P = 0.0211). There was no difference in the incidence of MACE between groups (30.6% Symbiot, 26.6% BMS, P = 0.43). Conclusions: This study failed to show an advantage for the Symbiot stent in the treatment of degenerated SVGs. This PTFE covered stent does not appear to act as a barrier to prevent restenosis.Keywords
This publication has 22 references indexed in Scilit:
- Feasibility, safety, and preliminary efficacy of a novel ePTFE‐covered self‐expanding stent in saphenous vein graft lesions: The Symbiot II trialCatheterization and Cardiovascular Interventions, 2005
- Cardiac Saphenous Vein Bypass Graft DiseaseSeminars in Vascular Medicine, 2004
- Randomized Evaluation of Polytetrafluoroethylene-Covered Stent in Saphenous Vein GraftsCirculation, 2003
- Initial clinical experience with distal protection using the FilterWire in patients undergoing coronary artery and saphenous vein graft percutaneous interventionCatheterization and Cardiovascular Interventions, 2002
- Results of the Jostent coronary stent graft implantation in various clinical settings: Procedural and follow‐up resultsCatheterization and Cardiovascular Interventions, 2002
- Membrane-covered stents: A new treatment strategy for saphenous vein graft lesionsCatheterization and Cardiovascular Interventions, 2001
- Long-term clinical outcome after stent implantation in saphenous vein graftsJournal of the American College of Cardiology, 1996
- Immediate results and late outcomes after stent implantation in saphenous vein graft lesions: The multicenter U.S. Palmaz-Schatz stent experienceJournal of the American College of Cardiology, 1995
- A new approach for the quantification of complex lesion morphology: The gradient field transform; Basic principles and validation resultsJournal of the American College of Cardiology, 1994
- Balloon angioplasty for the treatment of lesions in saphenous vein bypass graftsJournal of the American College of Cardiology, 1993