Evaluation of the one-point microcapsule agglutination test for diagnosis of leptospirosis.
- 1 January 1994
- journal article
- research article
- Vol. 72 (3) , 395-9
Abstract
We have developed a one-point microcapsule agglutination test (MCAT) for the serodiagnosis of leptospirosis. The MCAT kit was evaluated for use in humans by six WHO Collaborating Centres for Reference and Research on Leptospirosis. The laboratories classified their serum samples on the basis of the microscopic agglutination test (MAT) and the following screening tests: enzyme-linked immunosorbent assay (ELISA), macroscopic (slide) agglutination test, or the complement fixation test. The MCAT may in some instances give a positive result earlier in the course of the disease than MAT or the ELISA IgM; on the other hand, it did not detect antibodies against some serovars, for example, those of the Sejroe or Australis serogroup in Slovakia. In contrast, however, the MCAT detected antibodies to serovar hardjo (the same serogroup as Sejroe) in patients from the United Kingdom and the Russian Federation.This publication has 5 references indexed in Scilit:
- Evaluation of a passive microcapsule agglutination test for the screening of human leptospirosisEuropean Journal of Epidemiology, 1993
- One-point method for serological diagnosis of leptospirosis: a microcapsule agglutination testEpidemiology and Infection, 1987
- SONIC-VIBRATED LEPTOSPIRAE AS ANTIGENS IN THE COMPLEMENT FIXATION TEST FOR THE DIAGNOSIS OF LEPTOSPIROSIS1949