Urea kinetic modelling: comparison of three methods
- 1 January 1989
- journal article
- research article
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 13 (1-2) , 87-89
- https://doi.org/10.3109/03091908909030202
Abstract
It has been claimed that computed urea kinetic (UK) modelling in haemodialysed patients for the estimation of protein intake and of the relation between total dialyser urea clearance and distribution volume (Kt/V) leads to an overestimation of protein catabolic rate (PCR). In the present study three different methods of kinetic modelling for the determination of PCR and Kt/V are compared in 15 patients. The first method (MI) is the direct quantification method based on the collection of all urea eliminated from the body. The two other methods are based on an iterative computed calculation. The second method (MII) is the urea kinetic modelling method as described by Sargent. Dialyser clearances were measured directly and not estimated by theoretical extrapolation. The third method described here (MIII), is based on the indirect calculation of urea distribution volume (Vw) according to Watson and of dialyser clearances from this Vw and from pre-and post-dialysis urea concentrations. All three methods result in PCRs that are not significantly different (MI:1·04 ± 0·29; MII:1·07±0.28; MIII:1·05 ±0·24 mg/kg BW per 24 h; p >0·05). When the results are correlated, the following results are obtained: MI vs MII: r =0·76, p >0·001; MI vs MIII: r = 0·78, p > 0·001; MII vs MIII: r =0·90, p t/V virtually identical results were obtained for each of the methods under study. In conclusion, all methods under study seem equally reliable in determining mean PCR. The present data, obtained with directly measured dialyser urea clearances, do not confirm the earlier held opinion that computed modelling results in an Overestimation of PCR.Keywords
This publication has 8 references indexed in Scilit:
- Adequacy Studies of Fistula Single-Needle DialysisAmerican Journal of Kidney Diseases, 1987
- A mechanistic analysis of the National Cooperative Dialysis Study (NCDS)Kidney International, 1985
- Kinetic modeling: Applications in renal and related diseasesKidney International, 1983
- Kinetic modeling of hemodialysis, hemofiltration, and hemodiafiltrationKidney International, 1983
- Prevention of Prednisone-lnduced Negative Nitrogen BalanceAnnals of Internal Medicine, 1981
- Total body water volumes for adult males and females estimated from simple anthropometric measurementsThe American Journal of Clinical Nutrition, 1980
- Nitrogen balance during intermittent dialysis therapy of uremiaKidney International, 1978
- Lanthanum permeability of tight junctions along the collecting duct of the ratKidney International, 1975