Cavitation Damage in Polymer Aqueous Solutions
- 1 March 1985
- journal article
- Published by ASME International in Journal of Fluids Engineering
- Vol. 107 (1) , 134-138
- https://doi.org/10.1115/1.3242431
Abstract
Cavitation damage tests in polymer solutions are made with a vibratory cavitation apparatus. It is possible for this device to suppress the degradation of polymer by ultrasonic cavitation. Polymer solutions used are 100 wppm, 500 wppm, and 1000 wppm solutions of Polyox. The weight loss in 100 wppm Polyox solution is larger than that in water, but in 500 wppm and 1000 wppm Polyox solutions the weight losses after 60 min exposure to cavitation are relatively small. It is indicated that the cavitation damage in polymer solutions is subject to the effective influence of elastic properties of liquids.Keywords
This publication has 0 references indexed in Scilit: