Porous Electrodes Supported on Ion-Exchange Membranes as Electrochemical Detectors for Supercritical Fluid Chromatography
- 28 February 2004
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (7) , 2133-2137
- https://doi.org/10.1021/ac0351421
Abstract
A conveniently assembled electrochemical cell, exploiting a porous electrode supported on a moist perfluorinated ion-exchange polymer, is proposed for profitable electrochemical detection in supercritical fluid chromatography. It consists of a porous Pt working electrode, contacted by the mobile phase from the chromatographic column, which is chemically deposited onto one side of a Nafion membrane. The rear uncoated side of this membrane, acting as a solid polymer electrolyte, is contacted by an electrolyte solution (1 M NaCl) contained in an internal compartment equipped with a Pt counter electrode and a Ag/AgCl, Cl- 1 M reference electrode. Ferrocene, eluted with supercritical carbon dioxide through a Spherisorb column installed in a supercritical fluid chromatographic system, was used as electroactive prototype analyte to test the performance of this detector, which turned out to be quite better than that provided by a conventional on-line UV absorbance detector. The recorded peaks were characterized by both a good reproducibility (4.5%) and a linear dependence of their height and area, which extended over a wide concentration range (∼3 orders of magnitude). Moreover, they were not interfered by possible solvent front, unlike peaks recorded by the UV detector. The detection limit, estimated for a signal-to-noise ratio of 3 (4.2 × 10-11 mol), was lower by ∼1 order of magnitude than that found for the UV detector. Finally, the long-term stability of this detector was satisfactory in that only a ∼6% decrease in the current responses was observed after a rather long period (2 months) of continuous use.Keywords
This publication has 38 references indexed in Scilit:
- Amperometric detection of NO and NO2 in the ppb range with solid-polymer electrolyte membrane supported noble metal electrodesAnalytica Chimica Acta, 2001
- Determination of methane and other small hydrocarbons with a platinum–Nafion electrode by stripping voltammetryAnalytica Chimica Acta, 2001
- Prediction of retention behavior of ferrocene derivatives in supercritical fluid chromatographyAnalytica Chimica Acta, 1997
- Development of an Amperometric Detector for Packed Capillary Column Supercritical Fluid ChromatographyAnalytical Chemistry, 1997
- Electrochemical response to H2, O2, CO2 and NH3 of a solid-state cell based on a cation- or anion-exchange membrane serving as a solid polymer electrolyteAnalytica Chimica Acta, 1995
- Online Electrochemical Detectors for Supercritical Fluid ChromatographyAnalytical Chemistry, 1995
- Voltammetry of p-Benzoquinone and Anthracene at Poly(ethylene oxide)-Coated Microelectrodes in CO2-Based FluidsThe Journal of Physical Chemistry, 1994
- Characterization of the electroenzymic reduction of hydrogen peroxide in carbon dioxide by voltammetry with a chemically modified microelectrodeJournal of the American Chemical Society, 1993
- Electrodes supported on ion-exchange membranes as sensors in gases and low-conductivity solventsAnalytica Chimica Acta, 1989
- Effect of added water on voltammetry in near-critical carbon dioxideThe Journal of Physical Chemistry, 1987