Aging test and dynamic fatigue test of apatite‐wollastonite‐containing glass ceramics and dense hydroxyapatite
- 1 April 1987
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 21 (4) , 467-484
- https://doi.org/10.1002/jbm.820210407
Abstract
The purpose of this study is to examine the changes in mechanical strength of two bioactive ceramics in living tissue. An aging test and dynamic fatigue test were performed using apatite‐wollastonite‐containing glass ceramics (A · W – GC) and dense hydroxyapatite (HA). Specimens (5mm × 5mm × 25mm, abraded with No. 2000 Al2O3 powder) were implanted into subcutaneous tissue of rats for varying periods of time. The bending strength of aged samples was measured by the three‐point loading method. The bending strength of A · W – GC was greater than that of HA (P < 0.001). There was no reduction in bending strength for both A · W – GC and HA in living tissue. The n value of both A · W – GC and HA did not decrease significantly after implantation as assessed by the results of the dynamic fatigue test according to analysis of covariance. SEM‐EPMA showed that Si and Mg contents decreased, Ca content did not change, while P content increased in the surface of A · W – GC. The area where x‐ray intensity changed increased moderately after implantation. There were no changes in Ca and P at the interface between HA and soft tissue. In macroscopic and microscopic observations, specimens were found to be encapsulated with a thin layer of connective tissue. Foreign body giant cells, obteoblasts, or osteoclasts were not observed in the soft tissue. There was no bonding between ceramics and soft tissue.This publication has 23 references indexed in Scilit:
- Mechanical properties of a new type of apatite-containing glass-ceramic for prosthetic applicationJournal of Materials Science, 1985
- In vivo and in vitro aging of orthopedic aluminasJournal of Biomedical Materials Research, 1983
- A comparison of the mechanical behavior of aluminas in air and simulated body environmentsJournal of Biomedical Materials Research, 1981
- Subcritical Crack Growth in Dense Alumina Exposed to Physiological MediaJournal of the American Ceramic Society, 1980
- Use of fracture mechanics theory in lifetime predictions for alumina and bioglass‐coated aluminaJournal of Biomedical Materials Research, 1979
- Strength of a dense alumina ceramic after aging in vitroJournal of Biomedical Materials Research, 1978
- Strength and Dynamic Fatigue of Float Glass SurfacesJournal of the American Ceramic Society, 1975
- Mechanisms of Glass CorrosionJournal of the American Ceramic Society, 1973
- Dynamic and Static Fatigue of Silicate GlassesJournal of the American Ceramic Society, 1971