New Noninvasive Method for Coronary Flow Reserve Assessment

Abstract
Background —We tested the hypothesis that blood flow velocity could be recorded in the left anterior descending coronary artery (LAD) during transthoracic echocardiography by use of second harmonic echo Doppler modality along with contrast enhancement (intravenous Levovist) at rest and after pharmacologically induced maximal vasodilation to assess coronary flow reserve (CFR) with a totally noninvasive approach. Methods and Results —Fifty-six consecutive patients undergoing coronary angiography underwent transthoracic contrast-enhanced pulsed-wave Doppler recording of blood flow velocity in the LAD by use of harmonic color Doppler as a guide at rest and after maximal vasodilation by dipyridamole infusion. Contrast enhancement with the harmonic mode greatly improved the success rate of recording adequate pulsed-wave Doppler signal in the LAD. CFR was (mean±SD) 1.54±0.7 in patients with (group 1) and 2.79±0.9 in patients without (group 2) significant LAD stenosis (lumen narrowing >70%) ( P Conclusions —Contrast-enhanced transthoracic echo Doppler with the harmonic mode is a feasible and promising technique for assessing CFR in a totally noninvasive way.