Failure of stabilization of the spine with methylmethacrylate. A retrospective analysis of twenty-four cases.
- 1 October 1986
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 68 (8) , 1145-1157
- https://doi.org/10.2106/00004623-198668080-00003
Abstract
Twenty-four patients who had a major complication after attempted stabilization of the spine with methylmethacrylate were referred for treatment. The initial instability that necessitated stabilization was caused by a traumatic condition in fifteen of these patients and by a metastatic tumor in nine. The average length of time before failure of fixation was 208.3 days for the patients who had a traumatic condition and 193.7 days for those who had a neoplasm. In eleven patients a progressive neural deficit developed postoperatively, and in six others the recovery of neural function was possibly hindered by the cement. A deep wound infection developed in six patients, and in five of them treatment by removal of the methylmethacrylate and metal, followed by a prolonged period of cervical traction, was required. Loosening and failure of fixation was the most common complication--it occurred in twelve of the fifteen patients who had a traumatic lesion and in eight of the nine who had a neoplasm. Salvage operations that included removal of the cement and conventional bone-grafting procedures were performed in eleven of the twelve patients who had loosening associated with a traumatic lesion and in six of the eight who had loosening and a tumor. Stability was restored in every patient. Improved long-term results can be achieved by using grafts of iliac bone and triple-wire stabilization methods (a midline wiring between the spinous processes and two iliac-crest grafts, one on each side, wired to the posterior elements) instead of methacrylate in the primary treatment of traumatic injuries. The treatment of choice for instability caused by neoplastic destruction of two or more vertebral bodies includes a construct of methylmethacrylate anteriorly. However, if cement is used, early augmentation with posterior fusion of the spine and stabilization should be considered. As a rule, combined anterior and posterior stabilization is recommended for the reconstruction of a spine that is unstable due to neoplastic destruction. In general, whenever methylmethacrylate is used for spinal stabilization, it should be augmented with grafts of iliac bone to provide long-term stability.This publication has 10 references indexed in Scilit:
- The influence of skeletal implants on incidence of infection. Experiments in a canine model.Journal of Bone and Joint Surgery, 1985
- Vertebral body resection for epidural compression by malignant tumors. Results of forty-seven consecutive operative procedures.Journal of Bone and Joint Surgery, 1985
- The Evolution of Stability in Cervical Spinal Constructs Using Either Autogenous Bone Graft or Methylmethacrylate CementSpine, 1985
- The Use of Methylmethacrylate Cement as an Instantaneous Fusion Mass in Posterior Cervical Fusions: A Canine In Vivo Experimental ModelSpine, 1984
- Methylmethacrylate stabilization of the cervical spine.Journal of Bone and Joint Surgery, 1984
- The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis.Journal of Bone and Joint Surgery, 1983
- Methylmethacrylate stabilization for enhancement of posterior cervical arthrodesis in rheumatoid arthritis.Journal of Bone and Joint Surgery, 1982
- The use of methylmethacrylate for vertebral-body replacement and anterior stabilization of pathological fracture-dislocations of the spine due to metastatic malignant disease.Journal of Bone and Joint Surgery, 1981
- The effect of methylmethacrylate on bacterial phagocytosis and killing by human polymorphonuclear leukocytes.Journal of Bone and Joint Surgery, 1978
- The effect of methylmethacrylate on chemotaxis of polymorphonuclear leukocytes.Journal of Bone and Joint Surgery, 1978