Real‐time reverse transcriptase–polymerase chain reaction (RT–PCR) for measurement of cytokine and growth factor mRNA expression with fluorogenic probes or SYBR Green I
- 1 June 2001
- journal article
- research article
- Published by Wiley in Immunology & Cell Biology
- Vol. 79 (3) , 213-221
- https://doi.org/10.1046/j.1440-1711.2001.01002.x
Abstract
Real‐time quantitative reverse transcriptase–polymerase chain reaction (RT–PCR) is the method of choice for rapid and reproducible measurements of cytokine or growth factor expression in small samples. Fluorescence detection methods for monitoring real‐time PCR include fluorogenic probes labelled with reporter and quencher dyes, such as Taqman probes or Molecular Beacons and the dsDNA‐binding dye SYBR Green I. Fluorogenic (Taqman) probes for a range of human and rat cytokines and growth factors were tested for sensitivity and compared with an assay for SYBR Green I quantification using real‐time fluorescence monitoring (PE Applied Biosystems Model 7700 sequence detector). SYBR Green I detection involved analysis of the melting temperature of the PCR product and measurement of fluorescence at the optimum temperature. Fluorogenic probes provided sensitive and reproducible detection of targets that ranged from low (107 copies/ reaction) expression. SYBR Green I gave reproducible quantification when the target gene was expressed at moderate to high levels (≥1000 copies/reaction), but did not give consistently reproducible quantification when the target gene was expressed at low levels. Although optimization of melting temperature improved the specificity of SYBR Green I detection, in our hands it did not equal the reproducible sensitivity and specificity of fluorogenic probes. The latter method is the first choice for measurement of low‐level gene expression, although SYBR Green I is a simple and reproducible means to quantify genes that are expressed at moderate to high levels.Keywords
Funding Information
- Wellcome Trust
This publication has 20 references indexed in Scilit:
- QUANTIFICATION OF MURINE CYTOKINE mRNAs USING REAL TIME QUANTITATIVE REVERSE TRANSCRIPTASE PCRCytokine, 1999
- A novel method for real time quantitative RT-PCR.Genome Research, 1996
- Molecular Beacons: Probes that Fluoresce upon HybridizationNature Biotechnology, 1996
- An evaluation of competitor type and size for use in the determination of mRNA by competitive PCR.Genome Research, 1995
- TOLERANCE TO RAT LIVER ALLOGRAFTSTransplantation, 1994
- Intragraft cytokine mRNA levels in human liver allograft rejection analysed by reverse transcription and semiquantitative polymerase chain reaction amplificationTransplant Immunology, 1993
- Structure-Specific Endonucleolytic Cleavage of Nucleic Acids by Eubacterial DNA PolymerasesScience, 1993
- HEART ALLOGRAFTS IN MURINE SYSTEMSTransplantation, 1992
- RT-PCR artifacts from processed pseudogenes.Genome Research, 1991
- Cytokine Gene Expression: Analysis using Northern Blotting, Polymerase Chain Reaction and in situ HybridizationImmunological Reviews, 1991