Size Distribution of Fine Particles from Coal Combustion
- 1 January 1982
- journal article
- research article
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 215 (4528) , 13-19
- https://doi.org/10.1126/science.215.4528.13
Abstract
Measurements of the particle size distribution at the outlets of six coal-fired utility boilers showed a peak at a particle diameter near 0.1 micrometer. This submicrometer mode appears to be a general feature of coal combustion that results from a volatilization-condensation process in the boiler. At the boilers tested, the submicrometer mode contained 0.2 to 2.2 percent of the total fly ash mass. The importance of this mode is greater than its small quantity suggests because particles in the submicrometer size range are often much more difficult to collect with conventional particulate control devices than larger particles. Thus, the submicrometer mode may significantly influence the design and selection of future power plant emission controls. The particle mass in the submicrometer mode was correlated with the nitric oxide concentration in the flue gas. This correlation suggests that control of nitric oxide by modification of the combustion conditions may reduce the generation and emission of submicrometer particles.Keywords
This publication has 14 references indexed in Scilit:
- A submicron aerosol mode in flue gas from a pulverized coal utility boilerEnvironmental Science & Technology, 1980
- On the operation of the electrical aerosol analyzer at reduced pressuresJournal of Aerosol Science, 1980
- Emissions and particle-size distributions of minor and trace elements at two western coal-fired power plants equipped with cold-side electrostatic precipitatorsEnvironmental Science & Technology, 1979
- Size distribution of fine particulate emissions from a coal-fired power plantAtmospheric Environment (1967), 1976
- NOx control for stationary combustion sourcesProgress in Energy and Combustion Science, 1976
- Results of Field Measurements of Industrial Particulate Sources and Electrostatic Precipitator PerformanceJournal of the Air Pollution Control Association, 1975
- Submicron particles from a pulverized coal fired boilerAtmospheric Environment (1967), 1975
- A Portable Electrical Analyzer for Size Distribution Measurement of Submicron AerosolsJournal of the Air Pollution Control Association, 1974
- Toxic Trace Elements: Preferential Concentration in Respirable ParticlesScience, 1974
- Source test cascade impactorAtmospheric Environment (1967), 1970