Do blood cultures need continuous monitoring so that clinical action can be taken outside normal working hours?
Open Access
- 1 November 1995
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 48 (11) , 1067-1068
- https://doi.org/10.1136/jcp.48.11.1067
Abstract
Many automated blood culture reading systems monitor bacterial growth 24 hours a day but it is unclear if reacting to prompts indicating bacterial growth outside normal laboratory hours is of clinical benefit. An analysis of 50 blood cultures from 43 patients which had organisms seen on Gram films and had triggered positive out-of-hours showed that examination of the Gram film altered management of seven patients and the results of culture or sensitivity testing altered that of a further four. However, after review, it was felt the clinical outcome would not have been influenced by earlier intervention in any of these patients. We therefore consider that an out-of-hours service for dealing with positive blood cultures is not justified in our hospital. This conclusion may not apply universally, especially in hospitals where potential pathogens show less predictable antimicrobial sensitivity patterns.Keywords
This publication has 2 references indexed in Scilit:
- An eight-year survey of the antimicrobial susceptibility patterns of 85,971 bacteria isolated from patients in a district general hospital and the local communityJournal of Antimicrobial Chemotherapy, 1993
- Automated screening of blood cultures with the Malthus microbiological growth analyser.Journal of Clinical Pathology, 1988