Automated Method for Subtraction of Fluorescence from Biological Raman Spectra
Top Cited Papers
- 1 November 2003
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 57 (11) , 1363-1367
- https://doi.org/10.1366/000370203322554518
Abstract
One of the challenges of using Raman spectroscopy for biological applications is the inherent fluorescence generated by many biological molecules that underlies the measured spectra. This fluorescence can sometimes be several orders of magnitude more intense than the weak Raman scatter, and its presence must be minimized in order to resolve and analyze the Raman spectrum. Several techniques involving hardware and software have been devised for this purpose; these include the use of wavelength shifting, time gating, frequency-domain filtering, first- and second-order derivatives, and simple curve fitting of the broadband variation with a high-order polynomial. Of these, polynomial fitting has been found to be a simple but effective method. However, this technique typically requires user intervention and thus is time consuming and prone to variability. An automated method for fluorescence subtraction, based on a modification to least-squares polynomial curve fitting, is described. Results indicate that the presented automated method is proficient in fluorescence subtraction, repeatability, and in retention of Raman spectral lineshapes.Keywords
This publication has 10 references indexed in Scilit:
- Automated Fluorescence Rejection Using Shifted Excitation Raman Difference SpectroscopyApplied Spectroscopy, 2002
- Enhanced Chemical Classification of Raman Images Using Multiresolution Wavelet TransformationApplied Spectroscopy, 2001
- Curve Fitting and Linearity: Data Processing in Raman SpectroscopyApplied Spectroscopy, 2001
- Quantitative Raman Spectroscopy of Highly Fluorescent Samples Using Pseudosecond Derivatives and Multivariate AnalysisAnalytical Chemistry, 2001
- Enhanced Chemical Classification of Raman Images in the Presence of Strong Fluorescence InterferenceApplied Spectroscopy, 2000
- Near‐Infrared Raman Spectroscopy for In Vitro Detection of Cervical PrecancersPhotochemistry and Photobiology, 1998
- Near-Infrared Raman Spectrometer Systems for Human Tissue StudiesApplied Spectroscopy, 1997
- Application of Wavelet Transforms to Experimental Spectra: Smoothing, Denoising, and Data Set CompressionAnalytical Chemistry, 1997
- Fluorescence Rejection in Raman Spectroscopy by Shifted-Spectra, Edge Detection, and FFT Filtering TechniquesApplied Spectroscopy, 1995
- Mode-locked laser Raman spectroscopy. New technique for the rejection of interfering background luminescence signalsAnalytical Chemistry, 1974