Radiologists' Performance for Differentiating Benign from Malignant Lung Nodules on High-Resolution CT Using Computer-Estimated Likelihood of Malignancy
- 1 November 2004
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 183 (5) , 1209-1215
- https://doi.org/10.2214/ajr.183.5.1831209
Abstract
OBJECTIVE. The purpose of our study was to evaluate whether a computer-aided diagnosis (CAD) scheme can assist radiologists in distinguishing small benign from malignant lung nodules on high-resolution CT (HRCT). MATERIALS AND METHODS. We developed an automated computerized scheme for determining the likelihood of malignancy of lung nodules on multiple HRCT slices; the likelihood estimate was obtained from various objective features of the nodules using linear discriminant analysis. The data set used in this observer study consisted of 28 primary lung cancers (6-20 mm) and 28 benign nodules. Cancer cases included nodules with pure ground-glass opacity, mixed ground-glass opacity, and solid opacity. Benign nodules were selected by matching their size and pattern to the malignant nodules. Consecutive region-of-interest images for each nodule on HRCT were displayed for interpretation in stacked mode on a cathode ray tube monitor. The images were presented to 16 radiologists—first without and then with the computer output—who were asked to indicate their confidence level regarding the malignancy of a nodule. Performance was evaluated by receiver operating characteristic (ROC) analysis. RESULTS. The area under the ROC curve (Az value) of the CAD scheme alone was 0.831 for distinguishing benign from malignant nodules. The average Az value for radiologists was improved with the aid of the CAD scheme from 0.785 to 0.853 by a statistically significant level (p = 0.016). The radiologists' diagnostic performance with the CAD scheme was more accurate than that of the CAD scheme alone (p < 0.05) and also that of radiologists alone. CONCLUSION. CAD has the potential to improve radiologists' diagnostic accuracy in distinguishing small benign nodules from malignant ones on HRCT.Keywords
This publication has 28 references indexed in Scilit:
- Small Solitary Pulmonary Nodules (≤1 cm) Detected at Population-Based CT Screening for Lung Cancer: Reliable High-Resolution CT Features of Benign LesionsAmerican Journal of Roentgenology, 2003
- CT Screening for Lung CancerAmerican Journal of Roentgenology, 2002
- Usefulness of an Artificial Neural Network for Differentiating Benign from Malignant Pulmonary Nodules on High-Resolution CTAmerican Journal of Roentgenology, 2002
- Screening for Lung Cancer with Low-Dose Spiral Computed TomographyAmerican Journal of Respiratory and Critical Care Medicine, 2002
- High-Resolution CT Analysis of Small Peripheral Lung Adenocarcinomas Revealed on Screening Helical CTAmerican Journal of Roentgenology, 2001
- Early Lung Cancer Action Project: overall design and findings from baseline screeningThe Lancet, 1999
- The Probability of Malignancy in Solitary Pulmonary NodulesArchives of internal medicine (1960), 1997
- Quantification of Failure To Demonstrate Statistical SignificanceInvestigative Radiology, 1993
- ROC RATING ANALYSISInvestigative Radiology, 1992
- Receiver Operating Characteristic Rating AnalysisInvestigative Radiology, 1992