Benchmark Data from the Literature for Evaluation of New Glucose Sensing Technologies
- 1 September 2001
- journal article
- research article
- Published by Mary Ann Liebert Inc in Diabetes Technology & Therapeutics
- Vol. 3 (3) , 409-418
- https://doi.org/10.1089/15209150152607196
Abstract
New glucose sensors based on various technologies are being developed to provide information for improved therapy in diabetes. There is a need to establish rational performance standards for these sensors. Frequently sampled, direct blood glucose recordings representative of blood glucose excursions in diabetes are the "gold standard." An extensive literature search revealed a limited number of diabetic and nondiabetic blood glucose recordings suitable for this purpose. Certain blood glucose recordings reflect the diversity of glycemic dynamics and provide sufficient challenge for evaluation of sensor systems. These recordings were converted into an accessible electronic format. An example is given of the use of these benchmark data to estimate aliasing error, or the error due to insufficient sampling frequency, based on a hypothetical sensor system having some properties of conventional "fingerstick" systems. Discrete sampling systems accumulate substantial aliasing error as the sampling period increases.Keywords
This publication has 23 references indexed in Scilit:
- Noninvasive Glucose MonitoringJAMA, 1999
- In vitro and in vivo Performance and Lifetime of Perfluorinated Ionomer-Coated Glucose Sensors after High-Temperature CuringAnalytical Chemistry, 1994
- On Line Continuous Monitoring of Subcutaneous Tissue Glucose is Feasible by Combining Portable Glucosensor with MicrodialysisHormone and Metabolic Research, 1993
- In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissueBiosensors and Bioelectronics, 1992
- On line continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysisDiabetologia, 1992
- Combination of Microdialysis and Glucosensor Permits Continuous (On Line) s. c. Glucose Monitoring in a Patient Operated Device:I In Vitro EvaluationHormone and Metabolic Research, 1991
- Application of chronic intravascular blood glucose sensor in dogsDiabetes, 1990
- Progress in Practical EndocrinologyHormone and Metabolic Research, 1990
- Clinical usefulness of artificial endocrine pancreas "Biostator" in management of unstable diabetics.The Tohoku Journal of Experimental Medicine, 1983
- Urine glucose analyses during continuousPublished by American Medical Association (AMA) ,1972