Randomized Study of Peritonitis with Conventional versus O-Set Techniques in Continuous Ambulatory Peritoneal Dialysis
Open Access
- 1 April 1992
- journal article
- research article
- Published by SAGE Publications in Peritoneal Dialysis International
- Vol. 12 (2) , 216-220
- https://doi.org/10.1177/089686089201200207
Abstract
We performed a prospective randomized trial, comparing the incidence of peritonitis between a flushdisconnect (O-System, Baxter, Deerfield, IL) (OS) and a conventional (System II, Baxter) (CS) continuous ambulatory peritoneal dialysis (CAPD) method. Sixty consenting patients with no significant physical disabilities who commenced CAPD after May 1987 were entered and followed for a minimum of 12 months. Thirty were placed on the OS system and 30 were placed on CS. Age, gender, and time for training did not differ significantly. The period of observation for OS was 375 months; CS was observed for 430 months. OS patients experienced 28 episodes of peritonitis (13.4 months/patient/episode) compared with 88 (4.9 months/patient/episode) in CS (p<0.005). By 6 months, 32% of OS patients had had at least one episode of peritonitis, compared with 62% of CS patients; at 12 months, these figures rose to 48% for OS and 91% for CS (p<0.01) patients (Life Table Analysis). The median survival time to first peritonitis episode was 5.1 months in CS and 9.7 months in OS (p<0.01). Exit. site infections occurred in 14/30 (46%) of patients on OS and in 13/30 (43%) of CS patients. We conclude that the OS was associated with a significant reduction in the incidence of peritonitis.Keywords
This publication has 5 references indexed in Scilit:
- In Vitro Study of the Flush Effect in Two Reusable Continuous Ambulatory Peritoneal Dialysis (CAPD) Disconnect SystemsPeritoneal Dialysis International, 1989
- A Randomized Multicenter Clinical Trial to Evaluate the Effects of An Ultraviolet Germicidal System on Peritonitis Rate in Continuous Ambulatory Peritoneal DialysisPeritoneal Dialysis International, 1985
- PROSPECTIVE CONTROLLED TRIAL OF A Y-CONNECTOR AND DISINFECTANT TO PREVENT PERITONITIS IN CONTINUOUS AMBULATORY PERITONEAL DIALYSISThe Lancet, 1983
- A computer program for comparing K samples with right-censored dataComputer Programs in Biomedicine, 1972
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958