Magnetic Resonance Angiography With Gadomer-17
- 1 September 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 33 (9) , 699-708
- https://doi.org/10.1097/00004424-199809000-00026
Abstract
Our purpose was to investigate a "blood pool" contrast agent for abdominal and thoracic MR angiography by comparison with standard ionic and nonionic gadolinium-based contrast agents, which redistribute into the extracellular fluid compartment. Abdominal and thoracic MR angiography was performed in three adult dogs using a three-dimensional spoiled gradient echo pulse sequence before and after intravenous administration of one of three gadolinium-based contrast agents (gadopentetate dimeglumine, gadobutrol, and gadomer-17). Each compound was tested at five different doses in all three dogs. Quantitative analysis of signal-to-noise ratio (SNR) was performed in the aorta, inferior vena cava (IVC), liver, spleen, kidney (medulla and cortex), fat, and muscle. Gadomer-17 improved visualization of vascular anatomy at doses of 0.025, 0.05, 0.1, and 0.2 mmol/kg with three-fold greater aorta SNR during the arterial phase and more than four-fold greater aorta and IVC SNR during the equilibrium phase, in comparison with gadopentetate dimeglumine and gadobutrol at equal doses. Gadomer-17 is a promising contrast agent for both arterial phase and equilibrium phase MR angiography.Keywords
This publication has 17 references indexed in Scilit:
- MS-325: albumin-targeted contrast agent for MR angiography.Radiology, 1998
- Thoracic aorta: comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging.Radiology, 1997
- MR angiography with an ultrasmall superparamagnetic iron oxide blood pool agentJournal of Magnetic Resonance Imaging, 1997
- Gadolinium-enhanced three-dimensional MR angiography of the thoracoabdominal aortaSeminars in Ultrasound, CT and MRI, 1996
- Carboxymethyl-Dextran-Gadolinium-DTPA as a Blood-Pool Contrast Agent for Magnetic Resonance AngiographyInvestigative Radiology, 1996
- Evaluation of the effects of intravascular MR contrast media (gadolinium dendrimer) on 3D time of flight magnetic resonance angiography of the bodyJournal of Magnetic Resonance Imaging, 1996
- Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches.Radiology, 1995
- Angiographic properties of Gd-DTPA-24-cascade-polymer — a new macromolecular MR contrast agentEuropean Journal of Radiology, 1995
- Gadolinium-enhanced MR aortography.Radiology, 1994
- Dendrimer‐based metal chelates: A new class of magnetic resonance imaging contrast agentsMagnetic Resonance in Medicine, 1994