Abstract
We describe a dc volume H− source, employing multicusp plasma confinement, which has been constructed for use with the TRIUMF cyclotron. An extracted H− current density of 12 mA/cm2 has been obtained. Beam emittance and brightness have been measured as a function of current density and beam fraction. Beam brightness values for normalized beam emittances of the order of 0.2 πmm mrad at 81% beam fraction are typically 10 mA/(mm mrad)2 [equivalent rms B=223 mA/(mm mrad)2].Keywords
This publication has 4 references indexed in Scilit:
- Optimization of H− production in a magnetically filtered multicusp sourceReview of Scientific Instruments, 1985
- Extraction of H− beams from a magnetically filtered multicusp sourceReview of Scientific Instruments, 1984
- An Emittance Scanner for Intense Low-Energy Ion BeamsIEEE Transactions on Nuclear Science, 1983
- Calculations involving ion beam sourceJournal of Computational Physics, 1978