Colour Doppler ultrasound in the management of a case of cranial arteritis.
- 1 November 1992
- journal article
- case report
- Published by BMJ in British Journal of Ophthalmology
- Vol. 76 (11) , 690-691
- https://doi.org/10.1136/bjo.76.11.690
Abstract
Colour Doppler ultrasound allows simultaneous B scan and Doppler imaging and can be employed to determine the velocity of blood flow in the vasculature of the eye and orbit. We describe a case of cranial arteritis (giant cell arteritis) in which serial velocimetry recordings were obtained. At one stage in the disease process no blood flow was detectable in the orbit despite previously reliable recordings. This coincided with a deterioration of the clinical state of the patient as signified by recurrent anterior ischaemic optic neuropathy despite controlled symptomatology and erythrocyte sedimentation rate by prednisolone therapy. Subsequent increase in the immunosuppressive therapy was accompanied by a return of blood flow in the orbit. Colour Doppler ultrasound may prove to be a useful examination technique in the diagnosis and management of cranial arteritis.Keywords
This publication has 5 references indexed in Scilit:
- Color Doppler ultrasound of orbital and optic nerve blood flow: effects of posture and timolol 0.5%.1992
- Color Doppler Imaging of the Eye and OrbitArchives of Ophthalmology (1950), 1991
- Color Doppler ImagingArchives of Ophthalmology (1950), 1991
- Doppler Ultrasonography of Malignant Melanomas of the UveaArchives of Ophthalmology (1950), 1991
- Color Doppler flow imaging of the normal and abnormal orbit.Radiology, 1989