Laser probe ablation of normal and atherosclerotic human aorta in vitro: a first thermographic and histologic analysis.
- 1 December 1987
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 76 (6) , 1353-1363
- https://doi.org/10.1161/01.cir.76.6.1353
Abstract
The metal-tipped optical fiber or "laser probe" has been extensively studied in animal preparations in vivo and in human clinical trials of revascularization. The aim of this study was to evaluate the thermal characteristics of laser probe tissue ablation and to contrast the vascular tissue response to exposure to the laser probe and bare optical fiber. A 2 mm laser probe was heated with up to 4 W of argon-ion laser irradiation and applied to six postmortem strips of human nonatherosclerotic aorta as well as to five atherosclerotic aortic specimens. Surface temperature maps of the laser probe and of the vascular tissue in air were obtained via 8 to 12 micron thermographic imaging. Laser probe temperature was additionally monitored via thermocouples. Two strips each of normal and diseased aorta were irradiated directly with the bare optical fiber. Thus a total of 43 laser probe application sites and 19 bare fiberoptic laser irradiation sites on a total of 15 aortic strips were analyzed both thermographically and histologically. Based on measured temperature rises and histologic findings, the following observations were made: (1) The laser probe heats initially at its tip and attains a uniform surface temperature distribution within 5 sec. The steady-state temperature attained by the probe is inversely related to the thermal conductivity of the surrounding media. In all media studied, probe temperature increases linearly with applied laser energy. (2) Tissue ablation starts at temperatures greater than 100 degrees C, and ablation temperatures typically exceed 180 degrees C. Adventitial temperatures during laser probe application may reach 70 degrees C. Tissue ablation is enhanced both by greater laser energy deposition in the probe and by higher force at which the probe is applied to tissue. (3) Ablation of fibrofatty atheromata is more extensive than of nonatherosclerotic aortic tissue. This may be due to the lower thermal conductivity of atheromatous tissue. (4) In contrast to direct argon-ion laser ablation of aortic tissue, laser probe-mediated ablation occurs in a controlled fashion, is not associated with extensive subintimal dissections, and allows uniform conduction of heat to tissue as reflected by essentially "isothermal" injury lines.This publication has 11 references indexed in Scilit:
- Thermal effects of laser and electrical discharge on cardiovascular tissue: Implications for coronary artery recanalization and endocardial ablationJournal of the American College of Cardiology, 1986
- Laser angioplasty with angioscopic guidance in humansJournal of the American College of Cardiology, 1986
- PERCUTANEOUS LASER THERMAL ANGIOPLASTY: INITIAL CLINICAL RESULTS WITH A LASER PROBE IN TOTAL PERIPHERAL ARTERY OCCLUSIONSThe Lancet, 1986
- Some Physical Concepts in Laser AngioplastySeminars in Interventional Radiology, 1986
- Experimental angioplasty: Circumferential distribution of laser thermal energy with a laser probeJournal of the American College of Cardiology, 1985
- Effect of laser radiation on tissue during laser angioplastyLasers in Surgery and Medicine, 1985
- “Hot tip”: Another method of laser vascular recanalizationLasers in Surgery and Medicine, 1985
- The thermal response of laser irradiated tissueIEEE Journal of Quantum Electronics, 1984
- Effects of carbon dioxide, Nd-YAG, and argon laser radiation on coronary atheromatous plaquesThe American Journal of Cardiology, 1982