Transcutaneous estimation of arterial carbon dioxide in intensive care. Which electrode temperature?
Open Access
- 1 July 1986
- journal article
- research article
- Published by BMJ in Archives of Disease in Childhood
- Vol. 61 (7) , 652-656
- https://doi.org/10.1136/adc.61.7.652
Abstract
Transcutaneous and arterial carbon dioxide were measured simultaneously in 57 children (age range 10 days to 14.3 years) undergoing intensive care. All were haemodynamically stable at the time of study. Mean calibration time with 5 and 10% carbon dioxide was 43 (range 38-58) minutes and mean arterialisation time was 10.5 (range 3-30) minutes. Duplicate hourly arterial samples over a four hour period showed that transcutaneous: arterial carbon dioxide correlation was independent of electrode temperatures over the range 42-44 degrees C and was independent of child age. One and a half hours after electrode placement transcutaneous carbon dioxide (kPa) = arterial carbon dioxide X 1.41 + 0.02. Use of a simple ratio (arterial carbon dioxide = transcutaneous carbon dioxide/1.40) resulted in a mean estimate of arterial carbon dioxide within 3% of the actual value with coefficients of variation of 11 and 15% at 1.5 and 4.5 hours, respectively. For prediction of arterial carbon dioxide 95% confidence limits around the regression mean rose from +/- 1.04 kPa (7.8 mm Hg) at 1.5 hours to +/- 1.56 (11.7 mm Hg) at 4.5 hours. Baseline drift was more than +/- 0.67 kPa (5 mm Hg) during 22% of the studies. For a drift of less than 0.67 kPa 95% confidence limits were 0.87 and 1.12 kPa, respectively. Arterial carbon dioxide can be estimated with clinically acceptable tolerances from surface electrodes operating at temperatures between 42-44 degrees C. Improved electrode stability and speed of calibration should make this a valuable monitoring technique.Keywords
This publication has 13 references indexed in Scilit:
- Transcutaneous oxygen and carbon dioxide monitoring in intensive care.Archives of Disease in Childhood, 1985
- Transcutaneous monitoring in the newborn infantThe Journal of Pediatrics, 1983
- Reliability of Transcutaneous Oxygen Monitoring of Critically III Children in a General Pediatric UnitClinical Pediatrics, 1983
- CALIBRATION OF A HEATED TRANS-CUTANEOUS CARBON-DIOXIDE ELECTRODE TO REFLECT ARTERIAL CARBON-DIOXIDEPublished by Elsevier ,1983
- Continuous transcutaneous oxygen and carbon dioxide monitoring in the pediatric ICUCritical Care Medicine, 1982
- Transcutaneous PCO2 monitoring on adult patients in the ICU and the operating roomCritical Care Medicine, 1981
- Transcutaneous Oxygen Measurement in Adult Intensive CareActa Anaesthesiologica Scandinavica, 1979
- tcPCO2 electrode design, calibration and temperature gradient problems.1978
- Transcutaneous Po2 Monitoring in Routine Management of Infants and Children With Cardiorespiratory ProblemsPediatrics, 1976
- Effect of Temperature on Pco2 and Po2 of Blood in VitroJournal of Applied Physiology, 1956