A comparison of flow cytometric and absorption cytometric DNA values as prognostic indicators for pancreatic carcinoma
- 1 February 1993
- Vol. 71 (3) , 691-700
- https://doi.org/10.1002/1097-0142(19930201)71:3<691::aid-cncr2820710307>3.0.co;2-9
Abstract
Background. The DNA content of 30 adenocarcinomas of the head of the pancreas was measured by flow and absorption cytometric analysis. Methods. Each of the patients in this study had curative pancreatoduodenectomy. The absorption cytometric measurements were done in a research laboratory, and the flow cytometric measurements were performed in a commercial laboratory. The DNA measurements were done on nuclei disaggregated from pancreatic cancer tissue blocks without the examiner knowing whether the patient had survived. Results. Twenty-one of the 30 cancers were found to be aneuploid by absorption cytometric analysis, whereas only 1 of the 30 cancers was aneuploid by flow cytometric analysis. This difference was statistically significant (P < 0.001). Conclusions. Univariate and multivariate analyses showed that the absorption cytometric DNA measurements were stronger prognostic determinants for patient survival than were the flow cytometric DNA measurements, indicating that some caution may be warranted in the interpretation of commercially obtained DNA distributions of pancreatic carcinomas.Keywords
This publication has 30 references indexed in Scilit:
- Evaluation of DNA Nuclear Pattern as a Prognostic Determinant in Resected Pancreatic Ductal AdenocarcinomaAnnals of Surgery, 1992
- Pancreatic Cancer Cell DNA Content Correlates With Long-term Survival After PancreatoduodenectomyAnnals of Surgery, 1991
- Differences in the flow and absorption cytometric DNA distributions of mouse hepatocytes and tumor cellsCytometry, 1989
- DOUBTS ON "CURATIVE" RESECTION OF PANCREATIC CANCERThe Lancet, 1989
- Prediction of Relapse or Survival in Patients with Node-Negative Breast Cancer by DNA Flow CytometryNew England Journal of Medicine, 1989
- Comparison of absorption measurements of DNA stain content by utilizing video and scanning image cytometersCytometry, 1988
- Increased accuracy and speed of absorption cytometric DNA measurements by automatic corrections for nuclear darknessCytometry, 1984
- Increased accuracy of absorption cytophotometric DNA values by control of stain intensity.Journal of Histochemistry & Cytochemistry, 1981
- Cell Microfluorometry: A Method for Rapid Fluorescence MeasurementScience, 1969
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958