Initial experience in ablation of typical atrial flutter using a novel three-dimensional catheter tracking system
Open Access
- 2 August 2012
- journal article
- video audio-media
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 15 (4) , 578-581
- https://doi.org/10.1093/europace/eus226
Abstract
Three-dimensional (3D) mapping has been established for clinical routine in an interventional electrophysiology (EP). Recently, a novel sensor-based 3D catheter tracking system has been introduced integrating 3D non-fluoroscopic catheter navigation into the environment of pre-recorded 2D fluoroscopy [MediGuide™ Technology (MG)]. We are reporting on the first clinical experience for ablation of typical atrial flutter. First we aimed to demonstrate safety and feasibility of this new technique. Secondly, procedural aspects such as effectiveness, procedure, and fluoroscopy time should be evaluated. Ten consecutive patients (100% male, age 68 ± 8 years) were ablated using MG technology. Two steerable diagnostic EP catheters (MediGuide Enabled Livewire™ Catheter, SJM) were used for coronary sinus cannulation and anatomical cavo-tricuspidal isthmus (CTI) reconstruction within the EnSite NavX™ System (NavX). Ablation was performed with a conventional 8 mm tip ablation catheter (IBI, SJM). In all 10 patients both sensor-equipped MG catheters could be tracked non-fluoroscopically. Successful anatomical CTI reconstruction was performed and complete isthmus block was documented after the ablation. Total procedure duration was comparable with conventional procedures (55 ± 8 min). Usage of the MG tracking system resulted in a fluoroscopy time of 2.5 ± 2 min. No adverse events occurred during the procedures. For the first clinical application of the MG technology in an interventional electrophysiology we found a stable system enabling excellent 3D orientation for spatial catheter positioning on the basis of underlying pre-recorded cine loops. Clinically, the MG technology allowed successful procedures with short fluoroscopy times, even though a sensor-equipped ablation catheter was not yet available for use in the study.Keywords
This publication has 12 references indexed in Scilit:
- “Near-zero” fluoroscopic exposure in supraventricular arrhythmia ablation using the EnSite NavX™ mapping system: personal experience and review of the literatureJournal of Interventional Cardiac Electrophysiology, 2011
- Remote Magnetic Catheter Navigation for Cavotricuspid Isthmus Ablation in Patients With Common-Type Atrial FlutterCirculation: Arrhythmia and Electrophysiology, 2009
- Effect of Electroanatomically Guided Versus Conventional Catheter Ablation of Typical Atrial Flutter on the Fluoroscopy Time and Resource Use: A Prospective Randomized Multicenter StudyJournal of Cardiovascular Electrophysiology, 2009
- No fluoroscopy for cavotricuspid isthmus-dependent right atrial flutter ablationHeart Rhythm, 2009
- Antithrombotic Therapy in Atrial FibrillationChest, 2008
- Medical positioning system: a technical reportEuroIntervention, 2008
- Initial Clinical Experience with a Remote Magnetic Catheter Navigation System for Ablation of Cavotricuspid Isthmus‐Dependent Right Atrial FlutterPacing and Clinical Electrophysiology, 2008
- ACC/AHA/ESC Guidelines for the Management of Patients With Supraventricular Arrhythmias—Executive SummaryCirculation, 2003
- LocaLisaCirculation, 1999
- Nonfluoroscopic, in vivo navigation and mapping technologyNature Medicine, 1996