Material Properties of Cancellous Bone in Repetitive Axial Loading
- 1 October 1985
- journal article
- Published by SAGE Publications in Engineering in Medicine
- Vol. 14 (4) , 173-177
- https://doi.org/10.1243/emed_jour_1985_014_042_02
Abstract
Machined cancellous bone specimens from human cadaver knees were tested under repetitive nondestructive axial compression. Loads were applied up to 50 per cent of the ultimate strength of the specimens predicted from their mineral content measured by photon absorption technique. The stiffness increased greatly between the first two compressions, and thereafter asymptotically approached a constant level. There was a 44 per cent median increase in the modulus of elasticity from compression No. 1 to compression No. 10. Steady state was apparently reached after the fifth compression with intervals between compression cycles of not more than 2 minutes. The results were reproducible, and the precision of the modulus of elasticity determined by double measurement at compression No. 10 was Ē ± 9.8 per cent (95 per cent confidence limits). The modulus of elasticity at steady state determined as the mean of compressions 6–10 was found to be Ē ± 5.6 per cent (95 per cent confidence limits). With both methods there was a strong linear correlation between the ultimate strength and the modulus of elasticity. The correlation coefficient was r = 0.95 (p < 0.005) and r = 0.99 (p < 0.001), respectively.Keywords
This publication has 18 references indexed in Scilit:
- The mechanical properties of human tibial trabecular bone as a function of metaphyseal locationPublished by Elsevier ,2004
- Bone Mineral Assay: Its Relation to the Mechanical Strength of Cancellous BoneEngineering in Medicine, 1985
- Some Time Dependent Properties of the Intervertebral Joint when under CompressionEngineering in Medicine, 1984
- Analysis of compressive creep behavior of the vertebral unit subjected to a uniform axial loading using exact parametric solution equations of Kelvin-solid models—Part I. Human intervertebral jointsJournal of Biomechanics, 1984
- Cancellous Bone Strength at the Proximal Human TibiaEngineering in Medicine, 1984
- Effects of mechanical loading on the tissues of the rabbit kneeJournal of Orthopaedic Research, 1984
- Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial EpiphysisJournal of Biomechanical Engineering, 1982
- Analysis of load-deflection behavior of intervertebral discs under axial compression using exact parametric solutions of Kelvin-solid modelsJournal of Biomechanics, 1980
- Variations in strength and structure of cancellous bone at the kneeJournal of Biomechanics, 1974
- The Mechanical Properties of BoneClinical Orthopaedics and Related Research, 1970