Modeling 1H exchange: An estimate of the error introduced in MRI by assuming the fast exchange limit in bolus tracking
Open Access
- 26 March 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 51 (4) , 816-827
- https://doi.org/10.1002/mrm.20002
Abstract
A simulation is presented which calculates the MRI signal expected from a model tissue for a given pulse sequence after a bolus injection of a contrast agent. The calculation assumes two physiologic compartments only, the intravascular and extravascular spaces. The determination of the concentration of contrast in each compartment as a function of time and position has been outlined in a previous publication (Moran and Prato, Magn Reson Med 2001;45:42–45). These contrast agent concentrations are used here to determine the NMR relaxation times as a function of time and position within the tissue. Knowledge of this simulated tissue ‘map’ of relaxation times as a function of time provides the information required to determine whether the proton exchange rate is fast or slow on the NMR timescale. Since with a bolus injection the concentration of contrast and hence the relaxation time may vary with position along the capillary, some segments of the capillary are allowed to be in fast exchange with the extravascular space, while others may be in slow exchange. Using this information, and parameters specific to a given tissue, the MRI signal for a given pulse sequence is constructed which correctly accounts for differences in proton exchange across the length of the capillary. It is shown that extravascular contrast agents show less signal dependence on water exchange, and thus may be more appropriate for quantitative imaging when using fast exchange assumptions. It is also shown that nondistributed compartment models can incorrectly estimate the water exchange that is occurring at the capillary level if exchange‐minimizing pulse sequences are not used. Magn Reson Med 51:816–827, 2004.Keywords
This publication has 22 references indexed in Scilit:
- Quantification of the effect of water exchange in dynamic contrast MRI perfusion measurements in the brain and heartMagnetic Resonance in Medicine, 2001
- Effects of water exchange on the measurement of myocardial perfusion using paramagnetic contrast agentsMagnetic Resonance in Medicine, 1999
- Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolutionMedical Physics, 1998
- Water diffusion and exchange as they influence contrast enhancementJournal of Magnetic Resonance Imaging, 1997
- Improving MR quantification of regional blood volume with intravascular T1 contrast agents: Accuracy, precision, and water exchangeMagnetic Resonance in Medicine, 1996
- Measurement of the extraction efficiency and distribution volume for Gd‐DTPA in normal and diseased canine myocardiumMagnetic Resonance in Medicine, 1993
- Theory of contrast agents in magnetic resonance imaging: Coupling of spin relaxation and transportMagnetic Resonance in Medicine, 1992
- Pharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR ImagingJournal of Computer Assisted Tomography, 1991
- Measurement of the blood‐brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental conceptsMagnetic Resonance in Medicine, 1991
- Nuclear Magnetic Resonance Transverse Relaxation Times of Water Protons in Skeletal MuscleBiophysical Journal, 1974