Thresholding in PET images of static and moving targets
- 6 December 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (24) , 5969-5982
- https://doi.org/10.1088/0031-9155/50/24/014
Abstract
Continued therapeutic gain in the treatment of non-small-cell lung cancer (NSCLC) will depend upon our ability to escalate the dose to the primary tumour while minimizing normal tissue toxicity. Both these objectives are facilitated by the accurate definition of a target volume that is as small as possible. To this end, both tumour immobilizations via deep inspiratory breath-hold, along with positron emission tomography (PET), have emerged as two promising approaches. Though PET is an excellent means of defining the general location of a tumour focus, its ability to define exactly the geometric extent of such a focus strongly depends upon selection of an appropriate image threshold. However, in clinical practice, the image threshold is typically not chosen according to consistent, well-established criteria. This study explores the relationship between image threshold and the resultant PET-defined volume using a series of F-18 radiotracer-filled hollow spheres of known internal volumes, both static and under oscillatory motion. The effects of both image threshold and tumour motion on the resultant PET image are examined. Imaging data are further collected from a series of simulated gated PET acquisitions in order to test the feasibility of a patient-controlled gating mechanism during deep inspiratory breath-hold. This study illustrates quantitatively considerable variability in resultant PET-defined tumour volumes depending upon numerous factors, including image threshold, size of the lesion, the presence of tumour motion and the scanning protocol. In this regard, when using PET in treatment planning for NSCLC, the radiation oncologist must select the image threshold very carefully to avoid either under-dosing the tumour or overdosing normal tissues.Keywords
This publication has 25 references indexed in Scilit:
- Potential for reduced toxicity and dose escalation in the treatment of inoperable non–small-cell lung cancer: A comparison of intensity-modulated radiation therapy (IMRT), 3D conformal radiation, and elective nodal irradiationInternational Journal of Radiation Oncology*Biology*Physics, 2003
- Can PET provide the 3D extent of tumor motion for individualized internal target volumes? A phantom study of the limitations of CT and the promise of PETInternational Journal of Radiation Oncology*Biology*Physics, 2003
- Observer variation in contouring gross tumor volume in patients with poorly defined non-small-cell lung tumors on CT: the impact of 18 FDG-hybrid PET fusionInternational Journal of Radiation Oncology*Biology*Physics, 2001
- The effect of breathing and set-up errors on the cumulative dose to a lung tumorRadiotherapy and Oncology, 2001
- Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspirationInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Held-breath self-gating technique for radiotherapy of non–small-cell lung cancer: A feasibility studyInternational Journal of Radiation Oncology*Biology*Physics, 2001
- What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?Radiotherapy and Oncology, 1998
- Segmentation of lung lesion volume by adaptive positron emission tomography image thresholdingCancer, 1997
- Improved Survival in Stage III Non-Small-Cell Lung Cancer: Seven-Year Follow-up of Cancer and Leukemia Group B (CALGB) 8433 TrialJNCI Journal of the National Cancer Institute, 1996
- Tolerance of normal tissue to therapeutic irradiationPublished by Elsevier ,1991