Near-Infrared Detection of Flow Injection Analysis by Acoustooptic Tunable Filter-Based Spectrophotometry
- 1 January 1996
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (6) , 971-976
- https://doi.org/10.1021/ac951025x
Abstract
The instrumentation development of a near-infrared (near-IR) spectrophotometer based on an acoustooptic tunable filter (AOTF) and its application as a detector for flow injection analysis (FIA) are reported. In addition to being compact and all solid state, this AOTF-based instrument is very sensitive, has high resolution, and can be rapidly scanned. The latter advantage make it uniquely suited as a detector for FIA, in that it can rapidly record the whole near-IR absorption spectrum of a mixture passing through the FIA flow cell. Subsequent treatment of the recorded spectra with multivariate calibration methods makes it possible to use the FIA, for the first time, for such applications as the simultaneous determination of trace amounts of water and benzene in ethanol. Because all organic compounds absorb light in the near-infrared region, this AOTF-based near-IR detector can serve as a universal detector for FIA; as a consequence, applications of the FIA techniques can be expanded to other areas which are not possible otherwise.Keywords
This publication has 14 references indexed in Scilit:
- Flow Injection Gradient Technique in Spectrophotometric Determination of Formation Constants of Micromolecule-Cyclodextrin ComplexesAnalytical Chemistry, 1995
- Flow-injection determination of water in organic solvents by near-infrared spectrometryAnalytica Chimica Acta, 1993
- ISOTEC INC.Analytical Chemistry, 1992
- Radial measurement of hydrodynamically generated concentration profiles for molecular weight determinationAnalytical Chemistry, 1992
- Application of Multivariate Analyses to NIR Spectra of Gelatinized StarchApplied Spectroscopy, 1992
- Near-Infrared Fluorogenic Labels: New Approach to an Old ProblemAnalytical Chemistry, 1991
- LEE SCIENTIFICAnalytical Chemistry, 1990
- Sample Handling and Pretreatment Using Flow Injection AnalysisCritical Reviews in Analytical Chemistry, 1990
- Kinetic treatment of unsegmented flow systems : Part 5. Comprehensive Treatment for Systems with Gradient ChamberAnalytica Chimica Acta, 1989
- A highly sensitive flow-through phototransducer for unsegmented continuous-flow analysis demonstrating high-speed spectrophotometry at the parts per 109 level and a new method of refractometric determinationsThe Analyst, 1978