Generation of intense excimer radiation from high-pressure hollow cathode discharges
- 17 August 1998
- journal article
- Published by AIP Publishing in Applied Physics Letters
- Vol. 73 (7) , 885-887
- https://doi.org/10.1063/1.122027
Abstract
By reducing the diameter of the cathode opening in a hollow cathode discharge geometry to values on the order of 100 μm, we were able to operate these discharges in noble gases in a direct current mode up to atmospheric pressure. High-pressure discharges in xenon were found to be strong sources of excimer radiation. Highest intensities at a wavelength of 172 nm were obtained at a pressure of 400 Torr. At this pressure, the vacuum ultraviolet (VUV) radiant power of a single discharge operating at a forward voltage of 220 V and currents exceeding 2 mA reaches values between 6% and 9% of the input electrical power. The possibility to form arrays of these discharges allows the generation of flat panel VUV lamps with radiant emittances exceeding 50 W/cm2.Keywords
This publication has 6 references indexed in Scilit:
- Emission of excimer radiation from direct current, high-pressure hollow cathode dischargesApplied Physics Letters, 1998
- High-pressure hollow cathode dischargesPlasma Sources Science and Technology, 1997
- Microhollow cathode dischargesApplied Physics Letters, 1996
- Characteristics of electron-beam-excited Xe*2 at low pressures as a vacuum ultraviolet sourceJournal of Applied Physics, 1988
- UV excimer radiation from dielectric-barrier dischargesApplied Physics B Laser and Optics, 1988
- Enhancement by helium and argon of the formation rate of the 1720-Å-radiating states of Xe*2 excited by an E beamThe Journal of Chemical Physics, 1975