Radiation exposure benefit of a lead cap in invasive cardiology
Open Access
- 1 October 2003
- Vol. 89 (10) , 1205-1210
- https://doi.org/10.1136/heart.89.10.1205
Abstract
Background: Occupational head exposure to radiation in cardiologists may cause radiation induced cataracts and an increased risk of brain cancer. Objective: To determine the effectiveness of 0.5 mm lead equivalent caps, not previously used in invasive cardiology, in comparison with a 1.0 mm lead equivalent ceiling mounted lead glass screen. Design: An anthropomorphic Alderson-Rando phantom was used to represent the patient. Scatter entrance skin air kerma to the operator position (S-ESAK-O) was measured during fluoroscopy for all standard angulations and the S-ESAK-O per dose–area product (DAP) calculated, as applied to the phantom. Results: Measured mean (SD) left/right anterior oblique angulation ratios of S-ESAK-O without lead devices were 23.1 (10.1), and varied as a function of tube angulation, body height, and angle of incidence. S-ESAK-O/DAP decreased with incremental operator body height by 10 (3)% per 10 cm. A 1.0 mm lead glass shield reduced mean S-ESAK-O/DAP originating from coronary angiography from 1089 (764) to 54 (29) nSv/Gy × cm2. A 0.5 mm lead cap was effective in lowering measured levels to 1.8 (1.1) nSv/Gy × cm2. Both devices together enabled attenuation to 0.5 (0.1) nSv/Gy × cm2. The most advantageous line of vision for protection of the operator’s eyes was ⩾ 60° rightward. Conclusions: Use of 0.5 mm lead caps proved highly effective, attenuating S-ESAK-O to 2.7 (2.0) × 10−3 of baseline, and to 1.2 (1.4) × 10−3 of baseline where there was an additional 1.0 mm lead glass shield. These results could vary according to the x ray systems used, catheterisation protocols, and correct use of radiation protection devices.Keywords
This publication has 24 references indexed in Scilit:
- Abstract: Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85Annals of the ICRP, 2000
- Scatter dose estimation based on dose–area product and the specification of radiation barriersThe British Journal of Radiology, 1996
- Modifying fluoroscopic views reduces operator radiation exposure during coronary angioplastyJournal of the American College of Cardiology, 1994
- The dependence of the scattered radiation dose to personnel on technique factors in diagnostic radiologyThe British Journal of Radiology, 1992
- A 5-y Follow-up of the Radiation Exposure to In-room Personnel During Cardiac CatheterizationHealth Physics, 1992
- A survey of the radiation exposures received by the staff at two cardiac catheterization laboratoriesThe British Journal of Radiology, 1990
- An investigation of the radiation dose to staff during cardiac radiological studiesThe British Journal of Radiology, 1985
- Radiation exposure and protection in cardiac catheterization laboratoriesThe American Journal of Cardiology, 1985
- Operator radiation exposure during percutaneous transluminal coronary angioplastyJournal of the American College of Cardiology, 1984
- Radiation exposure to the operator performing cardiac angiography with U-arm systems.Circulation, 1978