Effects of intravoxel velocity distributions on the accuracy of the phase‐mapping method in phase‐contrast MR angiography
- 1 September 1994
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 4 (5) , 752-755
- https://doi.org/10.1002/jmri.1880040520
Abstract
The phase-mapping method of phase-contrast magnetic resonance angiography is shown to be based on an implicit assumption that the intravoxel velocity distribution is symmetric about its mean velocity. The effect of asymmetric distributions on the accuracy of quantitative average velocity measurements is determined analytically and verified experimentally. An explicit formulation is developed for the estimated average velocity in a voxel as a function of the true average velocity and the asymmetry of the distribution about the true average velocity. Worst-case distributions are determined for unidirectional and bidirectional flow, and the special case of laminar flow is also investigated. Computer simulations and phantom imaging experiments demonstrate the accuracy of the analysis. For voxels with unidirectional flow, the phase-mapping method produces accurate estimates of average velocity, while results for bidirectional flow indicate possible large errors unless the aliasing velocity is increased. which decreases the signal-to-noise ratio in the resultant velocity map image.Keywords
This publication has 11 references indexed in Scilit:
- Mr imaging of cerebral perfusion by phase‐angle reconstruction of bolus paramagnetic‐induced frequency shiftsMagnetic Resonance in Medicine, 1992
- MR angiography of the head and neck: value of two-dimensional phase-contrast projection technique.American Journal of Roentgenology, 1992
- Comparison of phase‐difference and complex‐difference processing in phase‐contrast MR angiographyJournal of Magnetic Resonance Imaging, 1991
- The application of phase shifts in NMR for flow measurementMagnetic Resonance in Medicine, 1990
- Measurement of mean and variance of velocity fields within each voxel by NMR imagingIEEE Transactions on Medical Imaging, 1988
- In Vivo Validation of MR Velocity ImagingJournal of Computer Assisted Tomography, 1987
- Blood Flow Imaging by Cine Magnetic ResonanceJournal of Computer Assisted Tomography, 1986
- Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference TechniqueJournal of Computer Assisted Tomography, 1984
- Direct Cardiac NMR Imaging of Heart Wall and Blood Flow VelocityJournal of Computer Assisted Tomography, 1984
- A flow velocity zeugmatographic interlace for NMR imaging in humansMagnetic Resonance Imaging, 1982