MALFUNCTION DETECTION OF THE DISTRIBUTOR IN A GAS-FLUIDIZED BED
- 1 March 1991
- journal article
- research article
- Published by Taylor & Francis in Chemical Engineering Communications
- Vol. 101 (1) , 103-114
- https://doi.org/10.1080/00986449108911605
Abstract
The malfunction of a perforated-plate distributor caused by blockage in a 0·3 m gas-fluidized bed was investigated in terms of pressure fluctuations. A pneumatic probe was used to detect the radial pressure distribution in the bed. The variation of pressure fluctuations in the bed was found to be in relationship to the perforated plate design and the static bed height while the plate was partially blocked. The bed pressure drop ratio was shown to be a clear indicator of plate blockage.Keywords
This publication has 7 references indexed in Scilit:
- Einsatz von Druckschwankungen zur Diagnostik von Störungen des Anströmbodens in einem WirbelschichtreaktorChemie Ingenieur Technik - CIT, 1987
- Visualization of gas voids behavior above the distributor in a three-dimensional gas fluidized bed.JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1986
- THE EFFECTS OF DISTRIBUTOR DESIGN ON FLUIDIZED-BED HYDRODYNAMIC BEHAVIORChemical Engineering Communications, 1985
- Gas entry effects in fluidized bed reactorsAIChE Journal, 1984
- FAULT DETECTION OF THE FLUIDIZED BED DISTRIBUTOR BY PRESSURE FLUCTUATION SIGNALChemical Engineering Communications, 1984
- A study of jets in a three-dimensional gas fluidized bedPowder Technology, 1982
- Pressure fluctuations in a fluidized bedAIChE Journal, 1981