Optical Transfer Function of Concave Grating Spectrometer Based on Wave Optical Method
- 1 December 1970
- journal article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 9 (12) , 1509-1516
- https://doi.org/10.1143/jjap.9.1509
Abstract
Optical transfer functions (OTF) of two types of spectrometer – Eagle mounting and Seya-Namioka mounting – are calculated by the wave-optical method which defines the OTF as the autocorrelation function of the pupil. Results obtained are compared with previous results of the present authors and interpreted as effects of diffraction and aberration on the broadening of point image. The OTFs are calculated also by Fourier transformation of the intensity distribution of point image and compared with those obtained by the first method.Keywords
This publication has 6 references indexed in Scilit:
- Étude ThÉorique Comparative de Deux Types de Monochromateurs à RÉseau Concave Pour L'ultra-violet LointainOptica Acta: International Journal of Optics, 1965
- Optimization of the Czerny–Turner Spectrometer*Journal of the Optical Society of America, 1964
- Geometrical Optical Image Formation in Infrared SpectrometersJournal of the Optical Society of America, 1960
- Theory of the Concave Grating III Seya-Namioka Monochromator*†‡Journal of the Optical Society of America, 1959
- Contrast Transfer in the Grating SpectrographOptica Acta: International Journal of Optics, 1959
- The Theory of the Concave GratingJournal of the Optical Society of America, 1945