New developments in scanning laser polarimetry for glaucoma
- 1 March 2008
- journal article
- review article
- Published by Wolters Kluwer Health in Current Opinion in Opthalmology
- Vol. 19 (2) , 136-140
- https://doi.org/10.1097/icu.0b013e3282f4b1c2
Abstract
Scanning laser polarimetry is a technique that is used to evaluate the thickness of the retinal nerve fiber layer. It has been shown to have a high accuracy for diagnosing glaucoma. In a subset of eyes, atypical retardation patterns may be present that do not match the expected retinal nerve fiber layer appearance. This review summarizes recent advances made to reduce the frequency and severity of these patterns. In addition, recent progress in the development of algorithms for detecting progression is discussed. A new measurement algorithm--enhanced corneal compensation--has been developed to improve the instrument's signal-to-noise ratio. Enhanced corneal compensation has been shown to improve the accuracy of scanning laser polarimetry for diagnosing glaucoma. In addition, enhanced corneal compensation improves the relationship between standard automated perimetry and scanning laser polarimetry measurements. Furthermore, research is being done on detecting progression in glaucoma. Recently, a method for simulating progression has been proposed, thereby diminishing the need for long-term studies to validate numerous measurement algorithms. With enhanced corneal compensation, the diagnostic accuracy of scanning laser polarimetry has been further improved for glaucoma. Newly developed algorithms for detecting any progressive retinal nerve fiber layer thinning await clinical validation.Keywords
This publication has 29 references indexed in Scilit:
- Is There Still a Clinical Use for Scanning Laser Polarimetry with Fixed Corneal Compensator?Ophthalmologica, 2006
- Effects of Inadequate Anterior Segment Compensation on Measurements With Scanning Laser PolarimetryOphthalmic Surgery, Lasers and Imaging Retina, 2006
- Diagnostic accuracy of the GDx VCC for glaucomaOphthalmology, 2004
- Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II ConfocalScanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomographfor the Detection of GlaucomaArchives of Ophthalmology (1950), 2004
- Visualization of localized retinal nerve fiber layer defects with the GDx with individualized and with fixed compensation of anterior segment birefringenceOphthalmology, 2003
- Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetryAmerican Journal of Ophthalmology, 2000
- Nerve Fiber Layer Defects with Normal Visual FieldsOphthalmology, 1993
- An Evaluation of Optic Disc and Nerve Fiber Layer Examinations in Monitoring Progression of Early Glaucoma DamageOphthalmology, 1992
- Clinically Detectable Nerve Fiber Atrophy Precedes the Onset of Glaucomatous Field LossArchives of Ophthalmology (1950), 1991
- Histopathologic Validation of Fourier-Ellipsometry Measurements of Retinal Nerve Fiber Layer ThicknessArchives of Ophthalmology (1950), 1990