Measurement of Paraquat in Serum by High-Performance Liquid Chromatography
Home
Publications
Measurement of Paraquat in Serum by High-Performance Liquid Chromatography
Measurement of Paraquat in Serum by High-Performance Liquid Chromatography
JM
J.J. Miller
J.J. Miller
ES
E. Sanders
E. Sanders
DW
D. Webb
D. Webb
Publisher Website
Google Scholar
Add to Library
Cite
Download
Share
Download
1 January 1979
journal article
Published by
Oxford University Press (OUP)
in
Journal of Analytical Toxicology
Vol. 3
(1)
,
1-3
https://doi.org/10.1093/jat/3.1.1
Abstract
A reliable and rapid assay for paraquat in serum and body fluids is described that is easily adaptable to most clinical biochemistry laboratories and allows for a more scientific approach to studies of paraquat pharmacokinetics and toxicology.